| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SA589 bảng dữ liệu(PDF) 3 Page - Sames |
|
|
|||||||||||||||||||||||||||||
SA589 bảng dữ liệu(HTML) 3 Page - Sames |
|
3 / 14 page ![]() SA589 FAMILY sames 3/14 Hookswitch Operation The HSW input is used to inform the SA589 of whether the telephone is on or off hook. Logic '0' is recognised as on-hook. Logic '1' is recognised as off-hook. When the HSW input rises from '0' to '1' the off-hook state is recognised immediately and keypad inputs are accepted. However, when the HSW input falls from '1' to '0' the on-hook state is not recognised for 200 - 300ms. This is so that short line breaks of less than 200ms, such as the line reversals applied by the exchange, are ignored. In this case the IMP and MASK outputs will go low immediately the HSW input goes low in order to preserve current, but will resume normal operation immediately HSW goes high. On-hook state In the on-hook state all chip outputs are set low, the oscillator circuit is inhibited and no key inputs are accepted. This conserves supply current so that the MEMORY contents may be retained. Off-hook state When the HSW input goes high, the MASK output immediately goes to the logic '1' level and remains there until going on-hook or signalling a TBR, (see timing diagram). COLUMN outputs also go high until a key is pressed and are normally off whenever timing functions are not required. Keypad Operation A Single Contact, Normally Open keypad is required. When off-hook the COLUMN outputs are normally held high and the ROW inputs are low. When a key is pressed this connects a COLUMN output to a ROW input and the ROW input is pulled high. This action initiates keyboard scanning. During keyboard scanning, the COLUMN outputs are normally low but generate scanning pulses at 7ms intervals on each output in sequence. A key is accepted as valid when two successive scanning pulses from the same COLUMN are seen on a ROW input. Hence, the minimum bounce-free key closure period which is necessary to guarantee detection is about 14ms (plus the oscillator start-up time if it was not already running). Simultaneous key depressions If two keys are pressed simultaneously (i.e. a second key is pressed before the first has been verified) neither key will be accepted until both keys are released and the correct key is pressed again. Dialling Mode Selection The dialling mode may be selected via the SELECT pin (Pin 4) as detailed in Table 2. Four 'Loop-Disconnect' + DTMF options, two 'Loop-disconnect only' options and three DTMF modes are available. Each mode offers a different combination of LD and/or MF timing. If one of the 'LD only' or DTMF only modes is selected then dialling will remain fixed in LD mode or DTMF mode respectively. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |