42 / 48 page ![]() Error responses SPBT2532C2.AT 42/48 Doc ID 16089 Rev 3 D.6 ErrUnknownCmd The ErrUnknownCmd error response will be sent if the requested command is not recognized. The unrecognized command will be echoed back to the host. Any parameters given will be ignored. AT-AB ErrUnknownCmd [unrecognized command] An accepted command always starts with the command identifier: AT+AB D.7 ErrInProgress ErrInProgress is sent in response to Discovery command being issued when the previous one is still in progress. AT+AB Discovery [unrecognized command] Examples of commands that produce this error response are given in the following table: Table 15. Example commands that generate <ErrInProgress> Example Reason AT+AB Discovery Trying to do discovery when the previous one has not completed. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|