8 / 24 page ![]() X28VC256 8 Figure 9. Write Sequence for Resetting Software Data Protection RESETTING SOFTWARE DATA PROTECTION Figure 8. Reset Software Data Protection Timing Sequence 3869 FHD F18 In the event the user wants to deactivate the software data protection feature for testing or reprogramming in an E2PROM programmer, the following six step algo- rithm will reset the internal protection circuit. After tWC, the X28VC256 will be in standard operating mode. Note: Once initiated, the sequence of write operations should not be interrupted. 3869 FHD F19 CE WE STANDARD OPERATING MODE VCC DATA ADDRESS AA 5555 55 2AAA 80 5555 tWC AA 5555 55 2AAA 20 5555 WRITE DATA 55 TO ADDRESS 2AAA WRITE DATA 55 TO ADDRESS 2AAA WRITE DATA 80 TO ADDRESS 5555 WRITE DATA AA TO ADDRESS 5555 WRITE DATA 20 TO ADDRESS 5555 WRITE DATA AA TO ADDRESS 5555 AFTER tWC, RE-ENTERS UNPROTECTED STATE |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|