| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MAX16005 bảng dữ liệu(PDF) 11 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX16005 bảng dữ liệu(HTML) 11 Page - Maxim Integrated Products |
|
11 / 26 page ![]() Low-Voltage, Quad-/Hex-/Octal-Voltage µP Supervisors ______________________________________________________________________________________ 11 Pin Description (MAX16006/MAX16007) (continued) PIN NAME FUNCTION 14 12 MARGIN Margin Disable Input. Pull MARGIN low to deassert all outputs (go into high state), regardless of the voltage at any monitored input. 15 — OUT4 Output 4. When the voltage at IN4 falls below its threshold, OUT4 goes low and stays low until the voltage at IN4 exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC. 16 — OUT3 Output 3. When the voltage at IN3 falls below its threshold, OUT3 goes low and stays low until the voltage at IN3 exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC. 17 — OUT2 Output 2. When the voltage at IN2 falls below its threshold, OUT2 goes low and stays low until the voltage at IN2 exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC. 18 — OUT1 Output 1. When the voltage at IN1 falls below its threshold, OUT1 goes low and stays low until the voltage at IN1 exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC. 19 15 RESET Active-Low Reset Output. RESET asserts low when any of the monitored voltages falls below its respective threshold or MR is asserted. RESET remains asserted for the reset timeout period after all monitored voltages exceed their respective thresholds and MR is deasserted. This open-drain output has a 30µA internal pullup. 20 16 IN1 Monitored Input Voltage 1. See Table 1 for the input voltage threshold. 21 17 IN2 Monitored Input Voltage 2. See Table 1 for the input voltage threshold. 22 18 IN3 Monitored Input Voltage 3. See Table 1 for the input voltage threshold. 23 19 IN4 Monitored Input Voltage 4. See Table 1 for the input voltage threshold. 24 20 TOL Threshold Tolerance Input. Connect TOL to GND to select 5% threshold tolerance. Connect TOL to VCC to select 10% threshold tolerance. — 8, 9, 13, 14 N.C. Not Internally Connected —— EP Exposed Pad. EP is internally connected to GND. Connect EP to the ground plane to provide a low thermal resistance path from the IC junction to the PCB. Do not use as the electrical connection to GND. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |