1 / 3 page

1/3
September 2007 / 311
www.sensortechnics.com
CLD Series
Continuous Level Detection Sensors
FEATURES
· Non-invasive ultrasonic technology
· Bottom-up liquid level measurements
· High accuracy and reliability
· Analog output voltage proportional to
liquid level
· Optional separate logic output to report
custom specific liquid level set points
SPECIFICATIONS
Maximum ratings
Supply voltage (V
S)
min. 6 V
DC, max. 24 VDC
Supply current
max.100 mA
Temperature limits
Operating
5...60 °C
Storage
-20...85 °C
Humidity limits
0 - 95 %RH
(non-condensing)