| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MPE-150S bảng dữ liệu(PDF) 2 Page - MicroPower Direct, LLC |
|
|
|||||||||||||||||||||||||||||
MPE-150S bảng dữ liệu(HTML) 2 Page - MicroPower Direct, LLC |
|
2 / 2 page ![]() Model Selection Guide Mechanical Dimensions Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Pin Function 1 AC-Line 2 AC-Neutral 3 AC-Ground 4 -Vout 5 -Vout 6 +Vout 7 +Vout Pin Connections MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Number Input Output Output Tolerance (%) Ripple & Noise (mV p-p) Efficiency (%, Typ) Current (A) Voltage (VDC) Current (A) 115 VAC 230 VAC Rated Adjust Rated Range MPE-150S-05 3.2 1.6 5.0 4.5 - 5.5 30.0 0 to 30.0 ±2.0 150 78 MPE-150S-09 3.2 1.6 9.0 8.0 - 10.4 16.7 0 to 16.7 ±1.0 180 80 MPE-150S-12 3.2 1.6 12.0 10.6 - 13.2 12.5 0 to 12.5 ±1.0 180 82 MPE-150S-13.5 3.2 1.6 13.5 12.0 - 15.0 11.2 0 to 11.2 ±1.0 180 83 MPE-150S-15 3.2 1.6 15.0 13.5 - 16.5 10.0 0 to 10.0 ±1.0 180 84 MPE-150S-24 3.2 1.6 24.0 21.0 - 28.0 6.5 0 to 6.5 ±1.0 240 85 MPE-150S-27 3.2 1.6 27.0 24.0 - 30.0 5.6 0 to 5.6 ±1.0 240 86 MPE-150S-48 3.2 1.6 48.0 43.0 - 53.0 3.2 0 to 3.2 ±1.0 240 87 Derating Curve Static Characteristics (24 Vout) Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regula- tion. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capaci- tor are connected in parallel as close to the power supply terminals as possible. 3. The overvoltage protection circuit shuts down the output. The unit must be repowered to recover once the fault condition is removed. 4. The overload protection circuit shuts down the out- put. The unit must be repowered to recover once the fault condition is removed. 5. Efficiency is measured with a 115 VAC input. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPE-150S series, a 7.5A/250 VAC slow blow should be used. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |