TL25XITWTAS bảng dữ liệu(PDF) 2 Page - Communications & Power Industries, Inc.

tên linh kiện TL25XITWTAS
Giải thích chi tiết về linh kiện  2.25 and 2.50 kW SuperLinear TWT Amplifiers
PDF  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  CPI [Communications & Power Industries, Inc.]
Trang chủ  http://www.cpii.com
Logo CPI - Communications & Power Industries, Inc.

TL25XITWTAS bảng dữ liệu(HTML) 2 Page - Communications & Power Industries, Inc.

  TL25XITWTAS Datasheet HTML 1Page - Communications & Power Industries, Inc. TL25XITWTAS Datasheet HTML 2Page - Communications & Power Industries, Inc.  
Zoom Inzoom in Zoom Outzoom out
 2 / 2 page
background image
X-Band
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 189, ISSUE 5
02/08
PDF
SPECIFICATIONS, TL22XI and TL25XI
Electrical
Frequency
7.9 - 8.4 GHz
Output Power
TWT - TL22XI
2250 W min. (63.54 dBm)
TWT - TL25XI
2500 W min. (63.98 dBm)
Flange - TL22XI
1000 W max. operating (60.00 dBm)
Flange - TL25XI
1110 W max. operating (60.45 dBm)
Linear Power
TL22XI
1000 W with linearizer option
TL25XI
1110 W with linearizer option3
Bandwidth
500 MHz
Gain
75 dB min. at rated power output
78 dB min. at small signal
RF Level Adjust
0 to 30 dB continuous
Output Power Adjustability
±0.1 dB
Gain Stability
±0.25 dB/24 hr max.
(at constant drive and temp.)
Small Signal Gain Slope
0.02 dB/MHz max.
Small Signal Gain Variation
0.5 dB pk-pk max. over any 40 MHz;
3.0 dB pk-pk max. across the
500 MHz band;
4.0 dB pk-pk w/linearizer;
5.0 dB pk-pk w/ BUC;
6.0 dB pk-pk w/linearizer and BUC
Input/Output VSWR
1.25:1 max.
Load VSWR
2.0:1 max. for full spec compliance;
any value without damage
Residual AM, max.1
-50 dBc below 10 kHz,
-20 (1.5 +log F kHz) dBc,
10 kHz to 500 kHz (F in kHz)
-85 dBc above 500 kHz
Phase Noise1
IESS-308/309
phase noise continuous
10 dB below mask at -10 dB backof
AC fundamentals related
-50 dBc
Sum of spurs
-47 dBc
AM/PM Conversion
6°/dB max. With optional linearizer,
can be tuned to 2°/dB max.
Harmonic Output
-80 dBc
Noise and Spurious
-130 dBW/4 kHz from 3.4 to 4.2 GHz
-65 dBW/4 kHz from 4.2 to 12.0 GHz
-110 dBW/4 kHz from 12.0 to 40.0 GHz
Intermodulation
-23.5 dBc max, 7.9 - 8.4 GHz
with two equal carriers,
(-25 dBc max. at 4 dB backoff
total output power
with linearizer);
level at 56 dBm
Electrical (continued)
Group Delay
0.02 ns/MHz linear
(in any 40 MHz band)
0.002 ns/MHz2 parabolic
0.5 ns pk-pk ripple max.
Primary Power2
All ratings are ±10%, 47-63 Hz, 5-wire,
3-phase with neutral and ground
208 VAC (with or w/o neutral)
380 to 415 VAC
Power Factor
0.95 min.
Power Consumption
5.5 kW max.;
4.9 kW typ. @ 1000 W linear RF output
power;
4.2 kW typ. @ 800 W;
3.9 kW typ. @ 600 W;
3.6 kW typ. @ 400 W;
3.3 kW typ. @ 200 W;
2.8 kW typ. @ 100 W
(Power consumption 10% less for
2.25 kW HPA, typ.)
Environmental
Ambient Temperature
-10° to +50°C operating
-40° to +71°C non-operating
Relative Humidity
95% non-condensing
Altitude
Up to 10,000 ft (3000 m) with standard
adiabatic derating of 2°/1000 ft.;
50,000 feet non-operating
Shock and Vibration
Designed for normal transportation
environment per Section 514.4
MIL-STD-810E. Designed to withstand
20g at 11 ms (1/2 sine pulse) in
non-operating condition
Mechanical
Cooling(TWT)
Forced air with integral blower
and power supply fan. Maximum
external pressure loss allowable:
0.25 inch water gauge.
RF Input Connection
Type N female
RF Output Connection
CPR 112 F waveguide flange,
grooved, threaded UNF 2B 10-32
RF Power Monitors
Type N female
Dimensions (W x H x D)
19 x 15.75 x 24 in.
(483 x 400 x 610 mm)
Weight
155 lbs. (70.5 kg) max.
1Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause
an increase in residual RF noise (AM, FM and PM). Phase noise increase is typically 2.5 dB / %
imbalance.
2AC current harmonic content: less than 20%, primarily fifth and seventh harmonics. Harmonics
must be considered when choosing UPS sources.
3Up to 1250 watts linear power available through optimization of linearizer settings.
OPTIONS &
COMP ANION
PRODUCTS:
• Integral Linearizer
• Remote Control Panel
• Redundant and Power
Combined Subsystems
• External Receive Band
Reject Filter
• Integral L-Band Block
Upconverter (BUC)
Certificate Number: 30515



Html Pages

1 2


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com