2 / 4 page ![]() SX500 10/98 REV B Page 2 Input Specifications Parameter Conditions Min Typ Max Units Operating Range 47-63 Hz 90 264 VAC Inrush Current Limiting Thermistor 120 VAC, cold start 30 APK 240 VAC, cold start 60 APK Active Current Limit 264 VAC 19 APK Efficiency Nominal line and full load 75 % Power Factor Correction (PFC) 0.99 Meets EN61000-3-2 (formerly IEC 555-2) Remote Sense Remote Sense is provided and will compensate for 1.0V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off (Optional) The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 115% of nominal voltage is typical. The power supply will latch off until AC power is cycled. Over Current Protection Automatic recovery upon fault removal. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 msec for a 25% step load. Reverse Voltage Protection The output is protected to rated load. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 10msec before loss of DC output. Upon AC input turn-on, signal remains low until output is in regulation. Consult the factory for other options. N+1 Load Share Output has active load sharing circuitry. Units will load share within 1% of the Maximum Rated Load. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety UL/CUL Recognized: UL File Number E13164 (1950) TUV License Number: R9773309 (EN60950) (IEC950) Cooling The unit is designed to operate with 30 CFM of airflow. DC Power Good Signal The signal is activated by a ±10% loss of regulation Active low or high; TTL Level; common with (-) sense. Consult the factory for other options. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |