  MTC600 Datasheet HTML 1Page - Emerson Network Power MTC600 Datasheet HTML 2Page - Emerson Network Power MTC600 Datasheet HTML 3Page - Emerson Network Power MTC600 Datasheet HTML 4Page - Emerson Network Power MTC600 Datasheet HTML 5Page - Emerson Network Power MTC600 Datasheet HTML 6Page - Emerson Network Power MTC600 Datasheet HTML 7Page - Emerson Network Power MTC600 Datasheet HTML 8Page - Emerson Network Power MTC600 Datasheet HTML 9Page - Emerson Network Power Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 19 page
background image
Rev. 05.26.08
MTC600 Series
5 of 19
Embedded Power for
Business-Critical Continuity
Output - All Models (continued)
3.3 V Outputs (Management Power) 5,6
Payload Power Interdependence
3.3 V must be applied before 12 V
Removal of 3.3 V also removes 12 V
and de-asserts ENABLE#
Setpoint
3.3 Vdc typical
Total Regulation Range
3.16 to 3.63 Vdc
Rated Load
8 W maximum
0.5 W / 150 mA maximum
Per Power Module
Per load channel
Minimum Load
No load
No loss of regulation
Output Rise TIme (per channel)
25 ms maximum
With 150 μF on output under test
Output Noise (PARD)3
50 mV maximum
75 mV maximum
0 to 30 MHz
0 to 100 MHz
Output Voltage Overshoot
2% maximum
Referenced to setpoint
Transient Response
3% maximum deviation
2 ms recovery time
37.5 mA loadstep @ 1 A/μs
Referenced to load current and setpoint at
onset of transient. Recovery time to within 1%
of setpoint at onset of transient
Voltage Sag
150 mV maximum
Primary PM to redundant PM transition with
max of 80 W load per output or 600 W load per
PM
Short Circuit Protection
225 mA maximum
12 ms maximum
Output to return
Channel Fault Operation
(Output to Return)
Output channel under fault is shutdown.
Both 3.3V and 12V are removed and
ENABLE# is de-asserted. The other channels
are not affected
After removal of fault, the output channel is
available again under control of the Carrier
Manager. PM_OK# is not de-asserted and
redundant failover is not initiated
Channel Fault Operation
(Output to Output)
No damage to Power Module
Either or both channels may
shut down until fault is removed
PS1# Extraction Delay
100 μs maximum
Time from de-assertion of PS1# to disabling of
the channel outputs and de-assertion of the
ENABLE# signal
Note 5: All channels and outputs must be configued by the carrier manager with the exception of MCH and CU channels and outputs
which are configured during Startup and/or autonomous operation.
Note 6: All measurements are made at the output connector of the Power Module. Unless otherwise specified,specs apply to all AMC,
MCH, and CU outputs.
Electrical Specifications (continued)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com