| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
R8C2K bảng dữ liệu(PDF) 188 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
R8C2K bảng dữ liệu(HTML) 188 Page - Renesas Technology Corp |
|
188 / 471 page ![]() R8C/2K Group, R8C/2L Group 16. Timers Rev.1.10 Dec 21, 2007 Page 171 of 450 REJ09B0406-0110 16.2.5.2 Programmable waveform generation mode The following three workarounds should be performed in programmable waveform generation mode. (1) To write to registers TRBPRE and TRBPR during count operation (TCSTF bit is set to 1), note the following points: • When the TRBPRE register is written continuously, allow three or more cycles of the count source for each write interval. • When the TRBPR register is written continuously, allow three or more cycles of the prescaler underflow for each write interval. (2) To change registers TRBPRE and TRBPR during count operation (TCSTF bit is set to 1), synchronize the TRBO output cycle using a timer RB interrupt, etc. This operation should be preformed only once in the same output cycle. Also, make sure that writing to the TRBPR register does not occur during period A shown in Figures 16.25 and 16.26. The following shows the detailed workaround examples. • Workaround example (a): As shown in Figure 16.25, write to registers TRBSC and TRBPR in the timer RB interrupt routine. These write operations must be completed by the beginning of period A. Figure 16.25 Workaround Example (a) When Timer RB interrupt is Used TRBO pin output Count source/ prescaler underflow signal Primary period Period A IR bit in TRBIC register Secondary period (b) Interrupt sequence Instruction in interrupt routine Interrupt request is acknowledged (a) Interrupt request is generated Ensure sufficient time Set the secondary and then the primary register immediately (a) Period between interrupt request generation and the completion of execution of an instruction. The length of time varies depending on the instruction being executed. The DIVX instruction requires the longest time, 30 cycles (assuming no wait states and that a register is set as the divisor). (b) 20 cycles. 21 cycles for address match and single-step interrupts. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |