37 / 46 page ![]() 10.2 Typical Applications 10.2.1 K-Type Thermocouple with Thermistor Cold-Junction Compensation The application example in Figure 10-9 shows how to use the ADS1x1C02 to monitor a K-Type thermocouple using a linear PTC thermistor for cold-junction compensation. 3.3V 3.3V AIN0 AIN1 AIN3 AIN2 I 2C Bus VDD SDA ADDR SCL ALERT/ RDY 0.1µF 1k to 10k (typ) Pullup Resistors 3.3V 1M 1M 3.3V RBias TMP61 10k Thermocouple RPU RPD 0.3nF 0.3nF 3nF CCM CCM CDIFF 1k 1k RTC RTC 500 RPTC 10nF CPTC ADS1x1C02 PGA 12/16-Bit ADC 1.024V Voltage Reference GND I 2C Interface Comparator Oscillator Temperature Sensor Mux Figure 10-9. K-Type Thermocouple Measurement Using a Thermistor for Cold-Junction Compensation 10.2.1.1 Design Requirements Table 10-1 lists the design requirements for this application. Table 10-1. Design Requirements DESIGN PARAMETER VALUE Supply Voltage 3.3V Thermocouple Type K Thermocouple Temperature Measurement Range –200°C to +1250°C Thermistor Type PTC Thermistor Temperature Measurement Range –40°C to +125°C Measurement accuracy at TA = 25°C(1) ±0.75 (1) Not accounting for error of the thermocouple and cold-junction temperature measurement; offset calibration at TTC = TCJ = 25°C; no gain calibration. 10.2.1.2 Detailed Design Procedure In this thermocouple measurement example, biasing resistors RPU and RPD set the common-mode voltage of the thermocouple to approximately mid-supply (VDD / 2) to keep the input voltages within the absolute input voltage range of the PGA. These biasing resistors are also useful in detecting an open thermocouple. An open thermocouple lead condition causes RPU and RPD to pull analog inputs AIN0 and AIN1 to VDD and GND respectively. Consequently, the ADC reads a full-scale value outside the normal measurement range, indicating a fault condition. Recommended values for RPU and RPD range from 1MΩ to 50MΩ to minimize self-heating and measurement errors. www.ti.com ADS101C01, ADS101C01L, ADS101C02, ADS101C02L ADS111C01, ADS111C01L, ADS111C02, ADS111C02L SBAS969 – SEPTEMBER 2026 Copyright © 2026 Texas Instruments Incorporated Submit Document Feedback 37 Product Folder Links: ADS101C01 ADS101C01L ADS101C02 ADS101C02L ADS111C01 ADS111C01L ADS111C02 ADS111C02L |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |