| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LT4HT-AC24VS bảng dữ liệu(PDF) 7 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
LT4HT-AC24VS bảng dữ liệu(HTML) 7 Page - Panasonic Semiconductor |
|
7 / 7 page ![]() Operation type Pulse One-shot Explanation Time chart • Set the operation mode section of the DIP switches (no.’s 1, 2, and 3) on the side of the timer as shown. • Clears elapsed time value at power ON. • Time delay starts and output control ON at start ON. • Turns output control OFF and clears elapsed time value at time-up. • Ignores start input during time delay. • Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. • In order to have the time delay start at power ON or reset at power OFF, short out the start input beforehand. D Pulse On delay E Signal Flicker F Totalizing On delay G OFF ON OFF ON OFF ON OFF ON OFF ON T T t1 t2 ta T=t1+t2 T>ta t Stop Start Reset Output Power supply OFF ON OFF ON OFF ON OFF ON OFF ON Tt2 T=t1+t2 T T t1 Stop Start Reset Output Power supply T>ta OFF ON OFF ON OFF ON OFF ON OFF ON t1 t1 T=t1+t2 T=t1+t2 ta t2 t2 T T T Stop Start Reset Output Power supply OFF ON OFF ON OFF ON OFF ON OFF ON T t1 t2 t3 ta T=t1+t2+t3 T>ta Stop Start Reset Output Power supply 123 ON ON OFF • Set the operation mode section of the DIP switches (no.’s 1, 2, and 3) on the side of the timer as shown. • Clears elapsed time value at power ON. • Time delay starts at start ON. • Ignores start input during time delay. • Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. • In order to have the time delay start at power ON or reset at power OFF, short out the start input beforehand. 123 OFF OFF ON • Set the operation mode section of the DIP switches (no.’s 1, 2, and 3) on the side of the timer as shown. • Clears elapsed time value at power ON. • Time delay starts at start ON. • Ignores start input during time delay. • Output control reverses, elapsed time value clears, and timer delay starts at timer comple- tion. • Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. • In order to have the time delay start at power ON or reset at power OFF, short out the start input beforehand. 123 ON OFF ON • Set the operation mode section of the DIP switches (no.’s 1, 2, and 3) on the side of the timer as shown. • Elapsed time value does not clear at power ON. (power outage countermeasure function) • The output remains ON even after the power is off and restarted. • Stops delay time operation at stop ON. Restarts delay time operation at stop OFF. 123 OFF ON ON LT4H/-L Notes: 1) Each signal input (start, reset, stop, and lock) is applied by shorting their input terminal to the common terminal (terminal Q for the 8-pin type, terminal E for the 11-pin type, and terminal for the screw terminal type). 2) The 8-pin type does not have a stop input or lock input. 6 T: Set time t1, t2, t3, ta<T All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |