18 / 28 page ![]() E2EW Series 18 PNP output Please contact your OMRON sales representative regarding assignment of data. 1. For models with IO-Link, the operation mode can be changed by the IO-Link communications. 2. If using a model with IO-Link as a general sensor or using a model without IO-Link, it operates in the standard I/O mode (SIO mode). 5 5 4 4 5 4 Sensing object (%) 100 0 80 20 Nonsensing area Unstable Sensing area Rated Sensing distance Stable Sensing area Set position ProximitySensor Excessive proximity judgment distance 7 Flashing (1sec cycle) Flashing (1sec cycle) Flashing (1sec cycle) Output mode Standard I/O mode (SIO mode) 2 NO+NC NO NC NO Operation mode 1 Comunication indicator (green) : Always OFF Operation indicator (orange) ON ON OFF ON OFF OFF Control output 3 Comunication indicator (green) : Always OFF Operation indicator (orange) ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Control output 3 Comunication indicator (green) : Always OFF Operation indicator (orange) Comunication indicator (green) Operation indicator (orange) Comunication indicator (green) Operation indicator (orange) Comunication indicator (green) Operation indicator (orange) Control output 1 3 Control output 2 3 1 0 1 0 1 0 1 0 1 0 1 0 1 0 Control output1 (PD1_bit0) 3 1 0 1 0 Excessive proximity detection (PD1_bit5) Control output (PD1_bit0) 3 Instability detection 6 (PD1_bit4) Excessive proximity detection (PD1_bit5) Control output (PD1_bit0) 3 Instability detection 6 (PD1_bit4) Excessive proximity detection (PD1_bit5) Instability detection 6 (PD1_bit4) 1 0 NC NO+NC ON OFF IO-Link Communication mode (COM mode) Control output2 (PD1_bit1) 3 Timing chart 3. The timer function of the control output can be set up by the IO-Link communications. (It is able to select ON delay, OFF delay, one-shot, or ONOFF delay function and select a timer time of 1 to 16,383ms (T).) 4. The excessive proximity diagnosis function can be selected by the IO- Link communications. 5. The instability detection diagnosis can be selected by the IO-Link communications. 6. The judgment time for the instability detection diagnosis can be selected by the IO-Link communications. (For the ON delay timer function, the setting can be selected from 0 (invalid), 10, 50, 100, 300, 500, or 1000 ms.) 7. The judgment distance of the excessive proximity diagnosis function can be selected by the IO- Link communications. (The distance can be selected as a combination of the material of the object detected, such as iron, aluminum, or SUS and the judgment distance of approximately 10, 20, or 30%. However, it is not allowed to select a combination of aluminum and 10%.) Please contact your OMRON sales representative regarding the IO-Link setup file (IODD file). ON delay OFF delay T T 1 0 1 0 NO NC ON OFF ON OFF Present Not present Sensing object T T NO NC ON OFF ON OFF 1 0 1 0 Present Not present Sensing object One shot ONOFF delay T T 1 0 1 0 NO NC ON OFF ON OFF Present Not present Sensing object T T T T 1 0 1 0 NO NC ON OFF ON OFF Present Not present Sensing object |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |