Back Button D41L-MP Datasheet HTML 13Page - Omron Electronics LLC D41L-MP Datasheet HTML 14Page - Omron Electronics LLC D41L-MP Datasheet HTML 15Page - Omron Electronics LLC D41L-MP Datasheet HTML 16Page - Omron Electronics LLC D41L-MP Datasheet HTML 17Page - Omron Electronics LLC D41L-MP Datasheet HTML 18Page - Omron Electronics LLC D41L-MP Datasheet HTML 19Page - Omron Electronics LLC D41L-MP Datasheet HTML 20Page - Omron Electronics LLC D41L-MP Datasheet HTML 21Page - Omron Electronics LLC  
Zoom Inzoom in Zoom Outzoom out
 20 / 21 page
background image
D41L
20
Set-up and Maintenance/Disassembly and Disposal
Set-up and Maintenance
Functional testing
The safety function of the safety components must be tested.
The following conditions must be previously checked and met:
1. Check maximum. axial misalignment of actuator and safety door
switch.
2. Check maximum. angular misalignment. (Refer to Mounting.)
3. Fitting and integrity of the cable connections.
4. Check the switch enclosure for damage.
5. Remove particles of dust and soiling.
6. For variants with an emergency exit, the following is to be
considered:
Note: 1. For variants with emergency exits it should be possible to
open the guard door inside the hazardous area; it should not
be possible to lock the guard door from inside.
Maintenance
Maintenance frequency
SIL3 / PLe at least once a month
SIL2 / PLd at least once a year
(Daily inspection)
• For each guard door, check that the machine stops when the guard
door opens.
(Inspection every 6 months)
• Check for a secure installation of the actuator and the safety door
switch
• Check maximum. axial misalignment of actuator and safety door
switch.
• Check maximum. angular misalignment. (Refer to Mounting.)
• Fitting and integrity of the cable connections.
• Check the switch enclosure for damages
• Remove soiling
Disassembly and Disposal
Disassembly
The product must be disassembled in a de-energized condition only.
Disposal
The product must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.
• Ecolab and its logo are registered trademarks of Ecolab USA Inc.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com