4 / 5 page ![]() Case Study CS-LD13 Rev. A Page 4 © 2025 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com According to the Lambert-Beer law, the area under the absorption profile is directly proportional to the density of ammonia measured which can be related to the pressure inside the cell. Using this, the calculated pressure inside the gas cell resulted in 1.65 ± 0.10 mbar which is in excellent agreement with both the analysis with a broader tuning range and with the precisely known pressure of 1.61 ± 0.01 mbar.1 Unlike cryogen-free spectrometers, the pyroelectric detector enables fast data acquisition and high sensitivity with its high bandwidth for avoiding deformations of the absorption features.1 To further demonstrate this design as a reliable detector for absorption spectroscopy measurements in the THz range, the noise level of the pyroelectric receiver was compared to that of the bolometer. Figure 5 shows the standard deviation of the noise of the absorption spectra as a function of total measurement time.1 Figure 5. Standard deviation of the noise of absorption spectra recorded with the bolometer (at a tuning frequency of 11 Hz) and the pyroelectric receiver (at a tuning frequency of 201 Hz) as a function of the total measurement time.1 The results for both the bolometer and pyroelectric receiver lie on a line with a slope of -0.5, as is expected for shot- noise limited detection. This implies that white noise is the dominating noise contribution for measurement times below 10 seconds.1 For single measurements with the pyroelectric receiver, the SNR is worse by approximately a factor of 10 compared to the SNR of single measurements performed by the bolometer. However, the SNRs of absorption spectra recorded with the same measurement time differ by only a factor of 2. Purging can improve the SNR by a factor of 3 to 4 depending on experiment humidity levels. Based on the noise measured, the resulting detection limits are 4 x 1014 cm-3 for the pyroelectric receiver, which is only a factor of 2 higher than the bolometer. This research demonstrates the successful implementation of a high-speed, cryogen-free pyroelectric receiver for terahertz absorption spectroscopy, offering a compact and efficient alternative to traditional helium-cooled detectors. The experimental setup enabled high-resolution spectral measurements with minimal noise and artifact-free absorption profiles, achieving data acquisition rates up to 281 Hz and frequencies up to 1 kHz are possible with a design upgrade. The results were in excellent agreement with known values obtained through other established methods, validating the reliability and accuracy of this innovative approach. By eliminating the need for cryogenic cooling, this design simplifies experimental setups and represents a significant step forward in advancing practical terahertz spectroscopy systems in a broad range of applications. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |