9790 bảng dữ liệu(PDF) 1 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
9790 bảng dữ liệu(HTML) 1 Page - Time Electronics Ltd. |
|
|
1 / 1 page ![]() Time Electronics 9790 100 A Current Transformer Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Description The 9790 is a heavy duty current transformer mounted in a steel case. It is suitable for use with Time Electronics 5025 and 5051 multifunction calibrators, as well as the 5077 power calibrator. It extends the AC current capability to 100 A RMS. The maximum compliance voltage is approximately 0.3 V at 100 A. In order to achieve this, very low resistance connecting leads must be used. Connection is via front mounted terminals. Operation To use the 9790 in testing applications the set up is straightforward but the appropriate leads and and connectors must be used. Connect the 20 A primary input terminals to the calibrator using suitable leads. Leads and connectors must be of low resistance and suitable for 20 A, recommended minimum wire size 4 mm2. Connect the 100 A secondary output terminals to the load using suitable leads. Leads and connectors must be of very low resistance and suitable for 100 A, recommended wire size 16 mm2, with a maximum outer diameter of 9 mm. Keep leads as short as possible. The total impedance of the secondary circuit at 50/60 Hz must be less than 3 mΩ for operation at 100 A. Specifications Current.....................................................................................100 A RMS maximum. VA rating...........................................................................................30 VA Maximum. Compliance............................. 0.3 V RMS at 100 A increasing to 0. 5 V rms at 20 A. Operating frequency ........................................................................... 50/6 0Hz only. Ratio error ..................................................... 5A to 50A 0.15 %. 50 A to 100A 0.2 %. Note: The final accuracy must be calculated as the Calibrator specification plus the 9790 Ratio Error. Phase error .......................... < 0.05° from 5 % to 120 % of full load current (100 A). Classification .................................... Conforms to BS EN6004-1 class 0.1 at 50 Hz. Dimensions .....................................................................W 317 x H 275 x D 177 mm Weight...............................................................................................................9.2 kg. Features • For use with the 5077 power calibrator • Compatible with the 5025/5051 multifunction calibrators • Robust clamp action 100 A terminals • 20 A input terminal posts take 4 mm plugs, spade connectors, or bare wired ends • Portable steel case with carry handle • Fully potted transformer with heavy duty internal connection • Primary and secondary phase connection clearly marked • Durable grey paint finish Due to continuous development Time Electronics reserves the right to change specifications without prior notice. v2b 07/22 Ordering Information 9790.......................................................100 A Current Transformer |
Số phần tương tự - 9790 |
|
Mô tả tương tự - 9790 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |