| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ILA-TIM-LEDIL-2A bảng dữ liệu(PDF) 3 Page - Intelligent LED Solutions |
|
|
|||||||||||||||||||||||||||||
ILA-TIM-LEDIL-2A bảng dữ liệu(HTML) 3 Page - Intelligent LED Solutions |
|
3 / 11 page ![]() © IGS Version V1 +44 (0)1635 294606 | info@i-led.co.uk | https://i-led.co.uk Intelligent LED Solutions, Unit 2, Berkshire Business Centre, Berkshire Drive, Thatcham, Berkshire, RG19 4EW A division of Intelligent Group Solutions Ltd 3 of 11 PRODUCT OPTIONS ILS Part Number IR centroid wavelength Radiant intensity IF = 1 A , tp = 10 ms Forward Voltage Radiance Angle Relevant Stanley LED Data ILR-IN01-85SL-LEDIL-SC221. 850nm 1150mW/sr 3.15-3.5V ±25° (50°) SFH4717AS ILR-IO01-85SL-LEDIL-SC221. 850nm 900mW/sr 3.15-3.4V ±40° (80°) SFH4715AS ILR-IW01-85SL-LEDIL-SC221. 850nm 350mW/sr 3.15-3.4V ±75° (150°) SFH4716AS ILR-IN01-94SL-LEDIL-SC221. 940nm 1150mW/sr 2.9-3.4V ±25° (50°) SFH4727AS ILR-IO01-94SL-LEDIL-SC221. 940nm 900mW/sr 2.9-3.4V ±40° (80°) SFH4725AS ILR-IW01-94SL-LEDIL-SC221. 940nm 350mW/sr 2.9-3.4V ±75° (150°) SFH4726AS Due to the special conditions of the manufacturing processes of LEDs, the typical data of technical parameters can only reflect overall statistical figures, and do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data. Tolerance +/- 10% Measured with 10mS 1000mA pulse at 25˚C MINIMUM AND MAXIMUM RATINGS ILS Part Number Operating Temperature at Tc-Point [˚C] Storage Temperature [˚C] Forward Current per chip [mA] Reverse Voltage [Vdc] ILR-IN01-85SL-LEDIL-SC221. -40 °C ~ 125 °C -40 °C ~ 125 °C 10-1500mA 5V ILR-IO01-85SL-LEDIL-SC221. -40 °C ~ 125 °C -40 °C ~ 125 °C 10-1500mA 5V ILR-IW01-85SL-LEDIL-SC221. -40 °C ~ 125 °C -40 °C ~ 125 °C 10-1500mA 5V ILR-IN01-94SL-LEDIL-SC221. -40 °C ~ 125 °C -40 °C ~ 125 °C 10-1500mA 5V ILR-IO01-94SL-LEDIL-SC221. -40 °C ~ 125 °C -40 °C ~ 125 °C 10-1500mA 5V ILR-IW01-94SL-LEDIL-SC221. -40 °C ~ 125 °C -40 °C ~ 125 °C 10-1500mA 5V Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED module. Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED module. The temperature of the LED module must be measured at the Tc-Point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |