| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
1089796 bảng dữ liệu(PDF) 3 Page - SICK AG |
|
|
|||||||||||||||||||||||||||||
1089796 bảng dữ liệu(HTML) 3 Page - SICK AG |
|
3 / 8 page ![]() SIG200-0A0512200 | SIG200 SENSOR INTEGRATION GATEWAY 4 LED yellow (To the IO-Link ports, Pin2 (DI)) 2 LED green (To the Ethernet ports) 1 LED green (For the Power Port) 1 LED dual-color (For module status communication) 1 LED green (For network status communication) Input/output characteristics S1-S4 pin 1 voltage supply ≤ 500 mA S1-S4 pin 4 output current ≤ 200 mA 4) Power Port pin 4 output voltage HIGH VH ≥ VUS - 3 V S1-S4 pin 2 input voltage Type 3 IEC 61131-2 S1-S4 pin 4 input voltage Type 1 IEC 61131-2 Enclosure rating IP67 Protection class III Housing material Zinc Housing color Light blue/Black Weight 520 g Dimensions (L x W x H) 213.9 mm x 57 mm x 38.3 mm UL File No. E497722 1) 10 - 30 V DC without IO-Link, 18 - 30 V DC with IO-Link. 2) Without sensors, outputs switched off. 3) The sum of all outputs, including the digital outputs, must not exceed the maximum current consumption of the device. The current consumption must be limited. 4) Pin 4 configured as digital output. The maximum output current does not depend on the voltage supply at pin 1 of S1-S4. Interfaces Communication interface IO-Link, USB, Ethernet, EtherNet/IP™, REST API Logic editor ✔ Web server ✔ IO-Link Master Function The SIG200 Sensor Integration Gateway is an IO-Link master with 4 configurable ports to which IO-Link device as well as binary switching sensors and actuators can be connected. The gate- way data is made available to a PLC or cloud application via the REST API. SIG200 can also be operated as a standalone system by directly configuring simple logic func- tions across several connected devices via the SOPAS ET user interface. IO-Link version V1.1, V1.0 Port Class A Number of IO-Link ports 4 Transmission type COM1, COM2, COM3 Operator interfaces SOPAS ET, the engineering tool for configuration via USB, Additionally, the SIG200 can be con- figured via the integrated webserver. Default IP adress: 192.168.0.1 MAC address See product label Number of inputs Max. 8 x PNP, type 1 or 4 x IO-Link Number of outputs Max. 4 x PNP Max. Output frequency 50 Hz Inputs/outputs S1-S4 4 configurable ports Pin4 can be used in one of the available port modes: IO-Link, digital input or digital output. An additional digital input signal can be connected using Pin2. LINK/ACT 1 & 2 Two Ethernet ports are provided for the network connection 2023-11-29 10:20:54 | Product data sheet Subject to change without notice INTEGRATION PRODUCTS | SICK 3 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |