| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
U2000/1/2H bảng dữ liệu(PDF) 7 Page - Keysight Technologies |
|
|
|||||||||||||||||||||||||||||
U2000/1/2H bảng dữ liệu(HTML) 7 Page - Keysight Technologies |
|
7 / 26 page ![]() Specifications Specifications contained in this chapter are valid ONLY after proper calibration of the power sensor and apply to continuous wave (CW) signals unless otherwise stated. The recommended calibration interval for this product is one year. Specifica- tions apply over a temperature range 0 to +55 °C unless otherwise stated. Specifications quoted over a tem- perature range of 25 °C ± 10 °C apply to a relative humidity of 15% to 75% and conform to the standard environ- mental test conditions. Specifications are valid after a 30-minute warm-up period. Supplemental characteristics, shown in italics, are intended to provide useful information with regard to ap- plying the power sensors in that they contain typical, but non-warranted performance parameters. These characteristics are shown in italics or denoted as “typical”, “nominal” or “approximate”. Measurement speed Normal: 20 readings/s x2: 40 readings/s Fast: 110 readings/s Buffered (50 readings): 1000 readings/s1 The U2000 Series USB sensors have two measurement modes: Average only mode (default mode): optimized for wide dynamic range. In this measurement mode, a trigger can be controlled externally via TTL input. Normal2 mode: used for making aver- age power measurement in a defined time interval (time-gated measure- ment) with reduced dynamic range. A trigger can be derived from an RF signal (internal trigger) or controlled externally via TTL input (external trigger). 1. The 1000 reading/s is the derived measurement speed from the first 50 readings in buff- ered mode. The maximum number of measurements that can be obtained in one second is 250 readings in buffered mode. 2. Not applicable for U2004A. Frequency and power ranges Model Frequency range Power range Maximum power U2000A 10 MHz to 18 GHz –60 to +20 dBm +25 dBm avg, 20 VDC +33 dBm pk, < 10 µs U2001A 10 MHz to 6 GHz U2002A 50 MHz to 24 GHz U2004A 9 kHz to 6 GHz –60 to +20 dBm +25 dBm avg, 5 VDC +33 dBm pk, < 10 µs U2000B 10 MHz to 18 GHz –30 to +44 dBm +45 dBm avg, 20 VDC +47 dBm pk, 1 µs U2001B 10 MHz to 6 GHz U2000H 10 MHz to 18 GHz –50 to +30 dBm +33 dBm avg, 20 VDC +50 dBm pk, 1 µs U2001H 10 MHz to 6 GHz U2002H 50 MHz to 24 GHz –50 to +30 dBm +33 dBm avg, 10 VDC +50 dBm pk, 1 µs Maximum SWR Model Frequency range Maximum SWR (25 °C ± 10 °C) Maximum SWR (0 °C to 55 °C) U2000A 10 to 30 MHz 30 MHz to 2 GHz 2 to 14 GHz 14 to 16 GHz 16 to 18 GHz 1.15 1.13 1.19 1.22 1.26 1.21 1.15 1.20 1.23 1.27 U2001A 10 to 30 MHz 30 MHz to 2 GHz 2 to 6 GHz 1.15 1.13 1.19 1.21 1.15 1.20 U2002A 50 MHz to 2 GHz 2 to 14 GHz 14 to 16 GHz 16 to 18 GHz 18 to 24 GHz 1.13 1.19 1.22 1.26 1.30 1.15 1.20 1.23 1.27 1.30 U2004A 9 kHz to 2 GHz 2 to 6 GHz 1.13 1.19 1.15 1.20 U2000B 10 MHz to 2 GHz 2 to 12.4 GHz 12.4 to 18 GHz 1.12 1.17 1.24 1.14 1.18 1.25 U2001B 10 MHz to 2 GHz 2 to 6 GHz 1.12 1.17 1.14 1.18 U2000H 10 MHz to 8 GHz 8 to 12.4 GHz 12.4 to 18 GHz 1.15 1.25 1.28 1.17 1.26 1.29 U2001H 10 MHz to 6 GHz 1.15 1.17 U2002H 50 MHz to 8 GHz 8 to 12.4 GHz 12.4 to 18 GHz 18 to 24 GHz 1.15 1.25 1.28 1.30 1.17 1.26 1.29 1.31 07 | Keysight | U2000 Series USB Power Sensors - Data Sheet |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |