| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SME312LP bảng dữ liệu(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SME312LP bảng dữ liệu(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 5 page ![]() Static Teach Sensor positions threshold between taught conditions Output OFF Output ON 2nd Taught Condition 1st Taught Condition The two sensing conditions may be presented in either order. The condition presented first is the condition for which the output will energize (the “Output ON” target). Sensitivity is automatically set (and optimized) when teaching the sensor the ON and OFF conditions. When the push button is clicked, the sensor samples each sensing condition and registers it into memory. After the second sensing condition is registered, the MINI-BEAM Expert automatically sets the sensitivity to the optimum value for the application, and then returns to RUN mode. Push button (0.04 seconds ≤ “Click” ≤ 0.8 seconds); Remote line (0.04 seconds ≤ “T” ≤ 0.8 seconds) 1. Access TEACH mode. Method Action Result Via push button Press and hold push button until the bi-color (green/ red) indicator begins to flash red, or turns OFF. Push button method only: The amber LED is on. The red LED pulses to indicate relative received signal strength. The sensor is ready for the output ON condition. Via remote line No action required; sensor is ready for 1st sensing condition. 2. Teach the first sensing condition. Method Action Result Via push button Present the first sensing condition and click the push button. The amber LED is off. The red LED pulses to indicate relative signal strength. The sensor registers the output ON condition and is ready for the output OFF condition. Via remote line Present the first sensing condition and single-pulse the remote line. 3. Teach the second sensing condition and return to RUN mode. Method Action Result Via push button Present the second sensing condition and click the push button. If the teach is accepted the green LED is on (or flashes if the signal is close to the switching threshold) and the amber LED is off until the sensing condition changes; the sensor registers the output OFF condition, positions the threshold, and returns to RUN mode. If the teach is not accepted, the amber LED is on and the red LED pulses to indicate the relative received signal strength. The sensor returns to its wait state and is ready for the first sensing condition. Via remote line Present the second sensing condition and single-pulse the remote line. NOTE: The sensor returns to RUN mode if the first TEACH condition is not registered within 90 seconds. TEACH mode may be cancelled before either the first or second condition by holding the push button depressed for more than two seconds. Enabling or Disabling the Push Button In addition to its programming function, the remote line may be used to disable the push buttons for security. Disabling the push buttons prevents undesired tampering with the sensor configuration settings. 1. Connect the sensor’s gray wire. 2. Four-pulse the remote line to enable or disable the push button. The sensor toggles between enable and disable settings and returns to RUN mode. MINI-BEAM Expert Series 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 68812 Rev. C |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |