công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

PX3AF1BS015PS bảng dữ liệu(PDF) 2 Page - Honeywell Solid State Electronics Center

tên linh kiện PX3AF1BS015PS
Giải thích chi tiết về linh kiện  Heavy Duty Pressure Transducers
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  HONEYWELL [Honeywell Solid State Electronics Center]
Trang chủ  http://honeywell.com/Pages/Home.aspx
Logo HONEYWELL - Honeywell Solid State Electronics Center

PX3AF1BS015PS bảng dữ liệu(HTML) 2 Page - Honeywell Solid State Electronics Center

  PX3AF1BS015PS Datasheet HTML 1Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 2Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 3Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 4Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 5Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 6Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 7Page - Honeywell Solid State Electronics Center PX3AF1BS015PS Datasheet HTML 8Page - Honeywell Solid State Electronics Center  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
2
Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Table 1. Electrical Specifications
Characteristic
Parameter
Supply voltage:
5 Vdc
3.3 Vdc
±0.25 Vdc
±0.25 Vdc
Over voltage and reverse voltage
±16 Vdc
Current consumption:
5 Vdc supply
3.3 Vdc supply
3.0 mA max.
1.6 mA to 2.1 mA
Short circuit protection
yes
Nominal output transfer function:
5 Vdc supply
3.3 Vdc supply
0.5 Vdc to 4.5 Vdc (ratiometric to supply)
0.33 Vdc to 2.97 Vdc (ratiometric to supply)
Table 2. Performance Specifications (At 25°C [77°F] and under unless otherwise noted.)
Characteristic
Parameter
Operating temperature range1
-40°C to 125°C [-40°F to 257°F]
Storage temperature range1
-40°C to 125°C [-40°F to 257°F]
Compensated temperature range
-40°C to 125°C [-40°F to 257°F]
Total Error Band2:
-20°C to 85°C [-4°F to 185°F]
<-20°C, >85°C [<-4°F, >185°F]
±1.0 %FSS
±2.0 %FSS
Accuracy BFSL3
±0.25 %FSS
Response time
<2 ms (10% to 90% step change in pressure)
Turn on time4
<7 ms
EMC rating5:
surge immunity (all leads)
electrostatic discharge
radiated immunity
fast transient burst
immunity to conducted disturbances
radiated emissions
radiated immunity
±1000 V line to ground per IEC 61000-4-5
±4 kV contact, ±8 kV air per IEC 61000-4-2
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3
±1 kV per IEC 61000-4-4
3 V per IEC 61000-4-6
40 dB (30 MHz to 230 MHz), 47 dB (230 MHz to 1000 MHz) per CISPR 11
200 V/m per ISO 11452-2
Insulation resistance
>100 MOhm, 1500 Vdc (in dry, non-ionized air)
Dielectric strength
AC1500V, 1 min. or AC1800V, 1 s (in dry, non-ionized air)
Load resistance
>5 kOhm
Life
greater than 10 million full scale pressure cycles over the calibrated pressure range
1
Dependent on external and internal seal and cable jacket materials. See Table 5 and Figure 5 for temperature range details.
2
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all
errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect
on span, and thermal hysteresis. See Figure 1.
3
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C
[77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. See Figure 1.
4
Turn on Time: Duration from power applied until first valid output.
5
Tested using 1.5 m [59.1 in] cable.
Table 3. Pressure Reference Definitions
Pressure Reference Definition
Absolute
Output is calibrated to be proportional to the difference between applied pressure and a fixed reference to
perfect vacuum (absolute zero pressure).
Sealed gage1
Sensor construction is identical to the absolute version with a built in reference at zero pressure in order to
minimize measurement error over temperature. The output is calibrated to be proportional to the difference
between applied pressure and a reference of 1 standard atmosphere (1.013 barA | 14.7 psiA). Example: 100
psi sealed gage has a calibrated pressure range from 14.7 psi absolute to 114.7 psi absolute. (See Figure 3.)
1
Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.



Html Pages

1 2 3 4 5 6 7 8


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com