70 / 159 page ![]() 7.3.1.1.5 Temperature Status Register (offset = 04h) [reset = N/A] Figure 7-5. Temperature Status Register 7 6 5 4 3 2 1 0 BUSY LHIGH LLOW RHIGH RLOW OPEN RESERVED RESERVED R-0h R-0h R-0h R-0h R-0h R-0h R-0h R-0h LEGEND: R/W = Read/Write; R = Read only; -n = value after reset Table 7-15. Temperature Status Register Field Descriptions Bit Field Type Reset Description 7 BUSY R 0h Temperature ADC status indicator 1 = ADC is converting. 0 = ADC is not converting. 6 LHIGH R 0h Local temperature high limit status indicator 1 = Local temperature value exceeds the Local Temperature High Limit Register value. This bit is cleared upon reading the Temperature Status Register providing that the condition causing the over temperature result is no longer present. 0 = Local temperature value does not exceed the Local Temperature High Limit Register value. 5 LLOW R 0h Local temperature low limit status indicator 1 = Local temperature value is below the Local Temperature Low Limit Register value. This bit is cleared upon reading the Temperature Status Register providing that the condition causing the under temperature result is no longer present. 0 = Local temperature value is not below the Local Temperature Low Limit Register value. 4 RHIGH R 0h Remote temperature high limit status indicator 1 = Remote temperature value exceeds the Remote Temperature High Limit Register value. This bit is cleared upon reading the Temperature Status Register providing that the condition causing the over temperature result is no longer present. 0 = Remote temperature value does not exceed the Remote Temperature High Limit Register value. 3 RLOW R 0h Remote temperature low limit status indicator 1 = Remote temperature value is below the Remote Temperature Low Limit Register value. This bit is cleared upon reading the Temperature Status Register providing that the condition causing the under temperature result is no longer present. 0 = Remote temperature value is not below the Remote Temperature Low Limit Register value. 2 OPEN R 0h Remote junction open circuit detection 1 = The remote junction is an open circuit. This bit is cleared upon reading the Temperature Status Register providing that the condition causing the open circuit is no longer present. 0 = The remote junction is not an open circuit. AFE10004-EP SLASFM1A – JUNE 2025 – REVISED DECEMBER 2025 www.ti.com 70 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: AFE10004-EP |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |