| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
062.08 bảng dữ liệu(PDF) 2 Page - Finder Relays, Inc. |
|
|
|||||||||||||||||||||||||||||
062.08 bảng dữ liệu(HTML) 2 Page - Finder Relays, Inc. |
|
2 / 14 page ![]() 62.32 / 62.33 62.32-0300 / 62.33-0300 2 CO (DPDT) 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm* 16/30** 16/30** 250/400 250/400 4,000 4,000 750 750 0.8/— 0.8/1.5 0.8/— 0.8/1.5 16/0.6/0.4 16/1.1/0.7 1,000 (10/10) 1,000 (10/10) AgCdO AgCdO 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 2.2/1.3 3/3 (0.8…1.1)UN (0.85…1.1)UN (0.8…1.1)UN (0.85…1.1)UN 0.8 UN/0.6 UN 0.8 UN/0.6 UN 0.2 UN/0.1 UN 0.2 UN/0.1 UN 10 · 10 6/30 · 106 10 · 10 6/30 · 106 100 · 10 3 100 · 10 3 11/4 15/3 6 6 1,500 2,500 –40…+70 –40…+50 RT I RT I • 2 & 3 pole changeover contact • Plug-in / Faston 187 • 2 & 3 pole normally open contact (≥ 3 mm contact gap) • Plug-in / Faston 187 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Motor rating (230/400 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power AC/DC VA (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kV Dielectric strength between open contacts V AC Ambient temperature range °C Environmental protection Approvals (according to type) * Distance between contacts ≥ 3 mm (EN 60730-1). **With the AgSnO2 material the maximum peak current is 120 A - 5 ms (NO contact). FOR UL RATINGS SEE: “General technical information” page V For outline drawing see page 10 Features Plug-in mount/Faston 187 16 A Power relay • Plug-in (92 series sockets) or Faston 187 (4.8x0.5 mm) with optional mounting adaptors • 2 & 3 Pole changeover contacts or NO (≥ 3 mm contact gap) • AC coils & DC coils • UL Listing (certain relay/socket combinations) • LED, mechanical indicator & test button options • Reinforced insulation between coil and contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance • SELV coil-contact separator option • Cadmium Free contact material options • Sockets and accessories • European Patent 2 62.32 62.33 62.32-0300 62.33-0300 62 SERIES 62 Series - Power relays 16 A A |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |