17 / 34 page ![]() DS6184 Rev 18 17/34 L5150CJ, L5150CS Application information 33 Reset pulse delay Trd is given by: Equation 2 trd = 32 x Tosc The Output Voltage Reset threshold can be adjusted via an external voltage divider R1 + R2 (R1 connected between Res_Adj and V0, R2 connected between Res_Adj and GND) according to the following formula: Equation 3 Vthre = [(R1 + R2) / R2] * VRes_adj The Output Voltage Reset threshold can be decreased down to 3.5 V. If it is needed to maintain it to its default value (8% below V0_ref typical), it is enough to connect the Res_Adj pin directly to GND. Figure 24. Reset time diagram Wi Vo Vcr Res < trr trr TOSC trd = 32 TOSC Vout_th VRhth VRlth GAPGCFT00054 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|