2 / 3 page ![]() MERSEN.COM MV 3 MEDIUM VOLTAGE FUSES FERRULE MOUNTED FUSES Amp-Trap CS-3 Series: (Indoors or outdoors in a weatherproof enclosure) A055F: 5.5kV – AC: 5E to 450E – 63kA I.R. Sym A825X: 8.25kV – AC: 10E to 200E – 70kA I.R. Sym A155F: 15.5kV – AC: 5E to 200E – 50 kA I.R. Sym 9F62 Series Type EJO-1: (Indoors and outdoors, to 80kA) 9F62: 5.5kV – AC: 25A to 450A – 50kA IR Sym 9F62: 8.3kV – AC: 20A to 250A – 50 kA IR Sym 9F62: 15.5kV – AC: 20A to 200A – 50 kA IR Sym 9F60 Series Type EJO-1: (Indoors and outdoors) 9F60: 2.75kV – AC: 1E to 200E – 50kA IR Sym 9F60: 5.5kV – AC: 0.5E to 200E – 50kA IR Sym 9F60: 8.25kV – AC: 0.5E to 200E – 50kA IR Sym 9F60: 15.5kV – AC: 0.5E to 100E – 50kA to 120kA IR Sym 9F60: 25.8kV – AC: 0.5E to 100E – 25kA to 35kA IR Sym 9F60: 38kV – AC: 1E to 80E – 13kA to 26kA IR Sym 9F60 Series Type EJ-1: (Indoors or outdoors in a weatherproof enclosure) 9F60: 2.75kV – AC: 1E to 200E – 47kA to 52kA IR Sym 9F60: 5.5kV – AC: 0.5E to 25E – 63kA IR Sym 9F60: 15.5kV – AC: 2E to 175E – 31kA to 82kA IR Sym 9F60: 25.8kV – AC: 0.5E to 2E – 35kA IR Sym 9F series A = 3.31 inches (84mm) 9F series B = 6.3 inches (160mm) Amp-Trap series A = 3.63 inches (92 mm) Amp-Trap series B = 6.63 inches (169 mm) Transformer Protection Amp-Trap® CS-3 Series and 9F60/9F62 Series DEFINITIONS: General Purpose Current-Limiting Fuses (Per IEEE Std C37.41-2016): A general purpose current-limiting fuse is one that is capable of interrupting all currents, from its rated maximum interrupting current down to a low value equal to the current that causes melting of the fuse elements in one hour or more, under specified conditions. E-Rating: E-Rated fuses operate as follows (per IEEE C37.42-2016): • 100E or less – must melt in 300 seconds (5 mins.) at 200 to 240% of E (ampere) rating. • Over 100E – must melt in 600 seconds (10 mins.) at 220 to 264% of E (ampere) rating. • Example: A 100E fuse must melt in 300 seconds with an applied current of 200 to 240 amperes. Power Distribution Fuses: Defines fuses designed prior to the time where the ANSI standards defined the term “General Purpose” and do not meet all of the general purpose definition. These fuses are capable of interrupting all currents above 2.2 to 3 times the fuse’s rated current up to its maximum interrupting rating. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |