| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
LM3697 bảng dữ liệu(PDF) 12 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM3697 bảng dữ liệu(HTML) 12 Page - Texas Instruments |
|
12 / 42 page ![]() To Assigned High Voltage Current Sinks PWM Input LPF Backlight Digital LED Control Block Full-Scale Current Select Brightness Setting Exponential or Linear Mapping Startup/Shutdown Ramp Generator Runtime Ramp Generator Analog Domain Digital Domain DAC Full-Scale Current Control polarity 12 LM3697 SNOSCS2D – NOVEMBER 2013 – REVISED MARCH 2019 www.ti.com Product Folder Links: LM3697 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated The PWM input accepts a logic level voltage and internally filters it to an analog control voltage. This results in a linear response of duty cycle to current, where 100% duty cycle corresponds to the programmed brightness code multiplied by the Full-Scale Current setting. Figure 9. PWM Input Architecture 7.3.5.1 PWM Input Frequency Range The usable input frequency range for the PWM input is governed on the low end by the cutoff frequency of the internal low-pass filter (540 Hz, Q = 0.33) and on the high end by the propagation delays through the internal logic. For frequencies below 2 kHz the current ripple begins to become a larger portion of the DC LED current. Additionally, at lower PWM frequencies the boost output voltage ripple increases, causing a non-linear response from the PWM duty cycle to the average LED current due to the response time of the boost. For the best response of current vs. duty cycle, the PWM input frequency must be kept between 2 kHz and 100 kHz. 7.3.5.2 PWM Input Polarity The PWM Input can be set for active low polarity, where the LED current is a function of the negative duty cycle. This is set via the PWM Configuration register (see Table 14). 7.3.5.3 PWM Zero Detection The LM3697 incorporates a feature to detect when the PWM input is near zero. After the near zero pulse width has been detected the PWM pulse must be greater than tPWM to affect the HVLED output current (see Electrical Characteristics ). Bit 3 in the PWM Configuration register is used to disable this feature. 7.3.6 Start-up/Shutdown Ramp The high-voltage LED start-up and shutdown ramp times are independently configurable in the start-up/shutdown transition time Register (see Table 6). There are 16 different start-up and 16 different shutdown times. The start- up times can be programmed independently from the shutdown times, but each Control bank is not independently configurable. The start-up ramp time is from when the Control Bank is enabled to when the LED current reaches its initial set point. The shutdown ramp time is from when the Control Bank is disabled to when the LED current reaches 0. 7.3.7 Run-Time Ramp Current ramping from one brightness level to the next is programmed via the Control A and B Run-Time Ramp Time Register (see Table 7). There are 16 different ramp-up times and 16 different ramp-down times. The ramp- up time can be programmed independently from the ramp-down time, but each Control Bank cannot be independently programmed. For example, programming a ramp-up or ramp-down time is a global setting for all high-voltage LED Control Banks. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |