Back Button TLV6003DBVR Datasheet HTML 11Page - Texas Instruments TLV6003DBVR Datasheet HTML 12Page - Texas Instruments TLV6003DBVR Datasheet HTML 13Page - Texas Instruments TLV6003DBVR Datasheet HTML 14Page - Texas Instruments TLV6003DBVR Datasheet HTML 15Page - Texas Instruments TLV6003DBVR Datasheet HTML 16Page - Texas Instruments TLV6003DBVR Datasheet HTML 17Page - Texas Instruments TLV6003DBVR Datasheet HTML 18Page - Texas Instruments TLV6003DBVR Datasheet HTML 19Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 26 page
background image
+
VREF
CE
WE
RE
Potentiostat (Bias Loop)
+
RF
Transimpedance Amplifier (I to V conversion)
RL
CO Sensor
VTIA
U1
U2
ISENS
R2
10 NŸ
C1
0.1µF
VREF
2.5V
Riso
49.9 k
C2
1µF
R1
10 k
15
TLV6003
www.ti.com
SLOS981 – OCTOBER 2019
Product Folder Links: TLV6003
Submit Documentation Feedback
Copyright © 2019, Texas Instruments Incorporated
8.2 Typical Application
Figure 32 shows a simple micropower potentiostat circuit for use with three-terminal unbiased CO sensors;
although, the design is applicable to many other type of three-terminal gas sensors or electrochemical cells.
The basic sensor has three electrodes: the sense or working electrode (WE), counter electrode (CE) and
reference electrode (RE). A current flows between the CE and WE proportional to the detected concentration.
The RE monitors the potential of the internal reference point. For an unbiased sensor, the WE and RE electrodes
must be maintained at the same potential by adjusting the bias on CE. Through the potentiostat circuit formed by
U1, the servo feedback action maintains the RE pin at a potential set by VREF.
R1 maintains stability due to the large capacitance of the sensor.
C1 and R2 form the potentiostat integrator and set the feedback time constant.
U2 forms a transimpedance amplifier (TIA) to convert the resulting sensor current into a proportional voltage. The
transimpedance gain, and resulting sensitivity, is set by RF according to Equation 1.
VTIA = (–I * RF) + VREF
(1)
RL is a load resistor with a value that is normally specified by the sensor manufacturer (typically, 10 Ω). The
potential at WE is set by the applied VREF.
Riso provides capacitive isolation and, combined with C2, form the output filter and ADC reservoir capacitor to
drive the ADC.
Figure 32. Three Terminal CO Gas Sensor



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com