Back Button IP178C-DS-R06 Datasheet HTML 21Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 22Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 23Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 24Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 25Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 26Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 27Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 28Page - List of Unclassifed Manufacturers IP178C-DS-R06 Datasheet HTML 29Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 93 page
background image
IP178C/IP178C LF/IP178CH/IP178CH LF
Datasheet
25/93
June 21, 2007
Copyright © 2004, IC Plus Corp.
IP178Cx-DS-R12
Pin description (continued)
Pin no.
Label
Type
Description
MII interface/ PHY mode
(Pin 53 EXTMII_EN =1, pin104 MII_MAC=0 and Pin72 RMII_MII =0)
101
MIICLK
IPL2/
O
MII transmit & receive clock
It is an output signal when MII works at PHY mode. It should be
connected to MII TXCLK & RXCLK of an external MAC device.
87,86,85
,81
TXD0~TXD3
IPL1
IPL1
IPL1
IPH2
MII transmit data
They are input signals when MII works at PHY mode. They are
sampled at the rising edge of MIICLK. They should be
connected to MII TXD of an external MAC device.
80
TXEN
IPH2
MII transmit enable
It is an input signal when MII works at PHY mode. It is used to
frame TXD [3:0]. It is sampled at the rising edge of MIICLK. It
should be connected to MII TXEN of an external MAC device.
75
RXDV
IPH1/
O
MII receive data valid
It is an output signal when MII works at PHY mode. It is used to
frame RXD [3:0]. It is sent out at the falling edge of MIICLK. It
should be connected to MII RXDV of an external MAC device.
79, 78,
77, 76
RXD0~RXD4
IPL1/
O,
IPL1/
O,
IPL1/
O,
IPH1/
O
MII receive data
They are output signals when MII works at PHY mode. They are
sent out at the falling edge of MIICLK. They should be
connected to MII RXD of an external MAC device.
56
NC
IPH2
This pin should be left open



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com