| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ATH.-7/U bảng dữ liệu(PDF) 3 Page - JUMO UK LTD |
|
|
|||||||||||||||||||||||||||||
ATH.-7/U bảng dữ liệu(HTML) 3 Page - JUMO UK LTD |
|
3 / 10 page ![]() M. K. JUCHHEIM GmbH & Co • 36035 Fulda, Germany Data Sheet 60.3021 Page 3/10 10.03/00073225 Electrical data Operating data Switching device ATH.-1 ATH.-2 ATH.-20 ATH.-7 ATH.-70 ATH.-7/U ATH.-70/U microswitch with changeover contact microswitch with break contact and lock-out microswitch with break contact, lock-out and additional signal contact Max. rating 10 (2) A, 230 V AC +10%, p.f. = 1 (0.6) 0.25A, 230 V DC +10% with differential 1.5% und 2% 6 (1.2) A, 230 V AC +10%, p.f. = 1 (0.6) –– microswitch gold-plated, code /au 0.1 A, 24 V AC / DC +10%, contact resistance 2.5 — 10 m Ω – Switching differential in % of control / limit range Switching function liquid-filled measuring system Nominal value Possible actual value TR, TW 33 max. 4 standard 66 max. 8 on request 1.5 1 max. 2 at extra charge gas-filled measuring system 54 max. 8 standard 98 max. 12 on request 2 1.5 max. 2.5 at extra charge liquid-filled measuring system STW (STB) 54 max. 6 standard 98 max. 11 on request 2 1 max. 3 at extra charge gas-filled measuring system 75 max. 12 standard 98 max. 16 on request 2 1.5 max. 3 at extra charge Switching point accuracy in % of control / limit range TR: in upper third of scale ± 1.5%, at start of scale ± 6% TW, TB, STB, STW (STB): in upper third of scale +0/-5%, at start of scale +0/-10% Ambient temperature error referred to control / limit range A deviation of the ambient temperature at the case from the 22 ° calibration ambient temperature produces a shift in the switching point: higher ambient temperature = lower switching point lower ambient temperature = higher switching point Surface-mounting thermostats with end-of-scale value < 200 °C ≥ 200°C ≤ 350°C > 350°C ≤ 500°C TR / TW / TB STB/STW (STB) TR / TW / TB STB/STW (STB) TR / TW / TB STB/STW (STB) due to thermostat head 0.08%/°C 0.17 %/°C 0.06%/°C 0.13 %/°C 0.14%/°C 0.12%/°C due to capillary per meter length 0.047 %/°C 0.054%/°C 0.09%/°C 0.11 %/°C 0.04%/°C 0.03%/°C Permissible storage temperature -50 to +50 °C Permissible ambient temperature in operation +80°C max. Nominal position (NL) to DIN 16 257, NL 0 — NL 90 (other NL on request) |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |