| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
R274-R274N-0576 bảng dữ liệu(PDF) 3 Page - GIACOMINI WATER E-MOTION |
|
|
|||||||||||||||||||||||||||||
R274-R274N-0576 bảng dữ liệu(HTML) 3 Page - GIACOMINI WATER E-MOTION |
|
3 / 8 page ![]() Actuator K274Y072 (optional) • Type of command: 2÷10 V • Opening time: 60 s • Maximum torque: 10 Nm • Electric absorption: 4,5 VA, 5 W • Insulation class: III • Protection degree: IP54 • Room working temperature range: 0÷50 °C • Room working humidity: 5÷95 % with non-condensing R.H. • Electric cable length: 1 m (6 x 0,5 mm2) • Possibility of manual control with maneuvering knob 6-way valves R274 and R274N • Fluid working temperature range: 5÷90 °C • Rated pressure (PN): 16 bar • Maximum differential pressure: 2 bar • Maximum glycol percentage: 50 % (the percentage of glycol must be equal for both circuits - heating and cooling) • Leakage rate (according to EN12266-1): A, no leakage • Connection for actuator: F04 - ISO 5211 Materials • Valve body: brass CW617N or CW602N (DZR) depending on version • Gaskets: low-friction PTFE / EPDM • Connection for actuator: PA66-GF30 Technical data Calibrated washers P21S (optional) Calibrated washers with seeger ring, made of stainless steel. Losses of pressure Loss of pressure values for valves R274Y033 and R274Y133 inclusive of delivery and return, with or without calibrated washers. PRODUCT CODE TOTAL Kv (VALVE DELIVERY AND RETURN + WASHER) Valve + P21SY001 0,25 (washer hole Ø 2,7 mm) Valve + P21SY002 0,40 (washer hole Ø 3,5 mm) Valve + P21SY003 0,65 (washer hole Ø 4,5 mm) Valve + P21SY004 1,00 (washer hole Ø 6,0 mm) Valve + P21SY005 1,30 (washer hole Ø 7,0 mm) Valve + P21SY006 1,60 (washer hole Ø 8,0 mm) Valve without P21S 1,90 0,1 0,01 1,0 10,0 Q [m3/h] 0,01 0,10 1,00 0,25 Kv: 0,4 0,65 1 1,3 1,61,9 Loss of pressure values for valves R274Y045, R274Y145, R274Y023, R274Y024 and R274Y025 inclusive of delivery and return, with or without calibrated washers. PRODUCT CODE TOTAL Kv (VALVE DELIVERY AND RETURN + WASHER) Valve + P21SY011 0,25 (washer hole Ø 3 mm) Valve + P21SY012 0,40 (washer hole Ø 4 mm) Valve + P21SY013 0,65 (washer holea Ø 4,5 mm) Valve + P21SY014 1,00 (washer hole Ø 5,8 mm) Valve + P21SY015 1,30 (washer hole Ø 6,7 mm) Valve + P21SY016 1,60 (washer hole Ø 7,5 mm) Valve + P21SY017 2,50 (washer hole Ø 9,0 mm) Valve + P21SY018 3,45 (washer hole Ø 12,7 mm) R274Y023 without P21S 3,45 R274Y024 without P21S 4,00 R274Y025/045/145 without P21S 4,25 WARNING. The valve is suitable for installation in indoor rooms and boiler rooms, and use with non-aggressive fluids (water, glycol-based water complying with VDI 2035/ÖNORM 5195). 0,1 0,01 1,0 10,0 Q [m3/h] 0,01 0,10 1,00 0,25 Kv: 0,4 0,65 1 1,3 1,6 2,5 3,45 4,0 4,25 3,45 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |