| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PAXUSB00 bảng dữ liệu(PDF) 6 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
PAXUSB00 bảng dữ liệu(HTML) 6 Page - Red Lion Controls. Inc |
|
6 / 32 page ![]() WARNING: Disconnect all power to the unit before installing Plug-in cards. Adding Option Cards The PAX and MPAX series meters can be fitted with up to three optional plug- in cards. The details for each plug-in card can be reviewed in the specification section below. Only one card from each function type can be installed at one time. The function types include Setpoint Alarms (PAXCDS), Communications (PAXCDC), and Analog Output (PAXCDL). The plug-in cards can be installed initially or at a later date. PAXI COMMUNICATION CARDS (PAXCDC) A variety of communication protocols are available for the PAX and MPAX series. Only one of these cards can be installed at a time. When programming the unit via Crimson, a Windows® based program, the RS232, RS485 or USB Cards must be used. Note: For Modbus communications use RS485 Communications Output Card and configure Communication Type parameter (tYPE) for Modbus. PAXCDC10 - RS485 Serial (Terminal) PAXCDC30 - DeviceNet PAXCDC1C - RS485 Serial (Connector) PAXCDC50 - Profibus-DP PAXCDC20 - RS232 Serial (Terminal) PAXUSB00 - USB (Mini B) PAXCDC2C - RS232 Serial (Connector) SERIAL COMMUNICATIONS CARD Type: RS485 or RS232 Communication Type: RLC Protocol (ASCII), Modbus RTU, and Modbus ASCII Isolation To Sensor & User Input Commons: 500 Vrms for 1 min. Working Voltage: 50 V. Not Isolated from all other commons. Data: 7/8 bits Baud: 1200 to 38,400 Parity: no, odd or even Bus Address: Selectable 0 to 99 (RLC Protocol), or 1 to 247 (Modbus Protocol), Max. 32 meters per line (RS485) Transmit Delay: Selectable for 0 to 0.250 sec (+2 msec min) DEVICENET™ CARD Compatibility: Group 2 Server Only, not UCMM capable Baud Rates: 125 Kbaud, 250 Kbaud, and 500 Kbaud Bus Interface: Phillips 82C250 or equivalent with MIS wiring protection per DeviceNet™ Volume I Section 10.2.2. Node Isolation: Bus powered, isolated node Host Isolation: 500 Vrms for 1 minute (50 V working) between DeviceNet™ and meter input common. PAXUSB PROGRAMMING CARD Type: USB Virtual Comms Port Connection: Type mini B Isolation To Sensor & User Input Commons: 500 Vrms for 1 min. Working Voltage: 50 V. Not Isolated from all other commons. Baud Rate: 1200 to 38,400 Unit Address: Selectable 0 to 99 (RLC Protocol), or 1 to 247 (Modbus Protocol) PROFIBUS-DP CARD Fieldbus Type: Profibus-DP as per EN 50170, implemented with Siemens SPC3 ASIC Conformance: PNO Certified Profibus-DP Slave Device Baud Rates: Automatic baud rate detection in the range 9.6 Kbaud to 12 Mbaud Station Address: 0 to 125, set by rotary switches. Connection: 9-pin Female D-Sub connector Network Isolation: 500 Vrms for 1 minute (50 V working) between Profibus network and sensor and user input commons. Not isolated from all other commons. PROGRAMMING SOFTWARE Crimson software is a Windows® based program that allows configuration of the PAX meter from a PC. Crimson offers standard drop-down menu commands, that make it easy to program the meter. The meter's program can then be saved in a PC file for future use. A PAX serial plug-in card or PAX USB programming card is required to program the meter using the software. SETPOINT CARDS (PAXCDS) The PAX and MPAX series has 4 available setpoint alarm output plug-in cards. Only one of these cards can be installed at a time. (Logic state of the outputs can be reversed in the programming.) These plug-in cards include: PAXCDS10 - Dual Relay, FORM-C, Normally open & closed PAXCDS20 - Quad Relay, FORM-A, Normally open only PAXCDS30 - Isolated quad sinking NPN open collector PAXCDS40 - Isolated quad sourcing PNP open collector DUAL RELAY CARD Type: Two FORM-C relays Isolation To Sensor & User Input Commons: 2000 Vrms for 1 min. Working Voltage: 240 Vrms Contact Rating: One Relay Energized: 5 amps @ 120/240 VAC or 28 VDC (resistive load), 1/8 HP @120 VAC, inductive load Total current with both relays energized not to exceed 5 amps Life Expectancy: 100 K cycles min. at full load rating. External RC snubber extends relay life for operation with inductive loads Response Time: 5 msec. nominal pull-in with 3 msec. nominal release Timed Output Accuracy: Counter = ± 0.01% + 10 msec. Rate = ± 0.01% + 20 msec. QUAD RELAY CARD Type: Four FORM-A relays Isolation To Sensor & User Input Commons: 2300 Vrms for 1 min. Working Voltage: 250 Vrms Contact Rating: One Relay Energized: 3 amps @ 250 VAC or 30 VDC (resistive load), 1/10 HP @120 VAC, inductive load Total current with all four relays energized not to exceed 4 amps Life Expectancy: 100K cycles min. at full load rating. External RC snubber extends relay life for operation with inductive loads Response Time: 5 msec. nominal pull-in with 3 msec. nominal release Timed Output Accuracy: Counter = ± 0.01% + 10 msec. Rate = ± 0.01% + 20 msec. QUAD SINKING OPEN COLLECTOR CARD Type: Four isolated sinking NPN transistors. Isolation To Sensor & User Input Commons: 500 Vrms for 1 min. Working Voltage: 50 V. Not Isolated from all other commons. Rating: 100 mA max @ VSAT = 0.7 V max. VMAX = 30 V Response Time: Counter = 25 µsec; Rate = Low Update time Timed Output Accuracy: Counter = ± 0.01% + 10 msec. Rate = ± 0.01% + 20 msec. QUAD SOURCING OPEN COLLECTOR CARD Type: Four isolated sourcing PNP transistors. Isolation To Sensor & User Input Commons: 500 Vrms for 1 min. Working Voltage: 50 V. Not Isolated from all other commons. Rating: Internal supply: 24 VDC ± 10% , 30 mA max. total External supply: 30 VDC max., 100 mA max. each output Response Time: Counter = 25 µsec; Rate = Low Update time Timed Output Accuracy: Counter = ± 0.01% + 10 msec. Rate = ± 0.01% + 20 msec. PAXI ANALOG OUTPUT CARD (PAXCDL) Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available from the analog output plug-in card. The programmable output low and high scaling can be based on various display values. Reverse slope output is possible by reversing the scaling point positions. PAXCDL10 - Retransmitted Analog Output Card ANALOG OUTPUT CARD - Self-Powered Output (Active) Types: 0 to 20 mA, 4 to 20 mA or 0 to 10 VDC Isolation To Sensor & User Input Commons: 500 Vrms for 1 min. Working Voltage: 50 V. Not Isolated from all other commons. Accuracy: 0.17% of FS (18 to 28°C); 0.4% of FS (0 to 50°C) Resolution: 1/3500 Compliance: 10 VDC: 10 KΩ load min., 20 mA: 500 Ω load max. Response Time: 50 msec. max., 10 msec. typ. 6 OpTiOnal plug-in OuTpuT Cards |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |