| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ADRF5422BCZ bảng dữ liệu(PDF) 4 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADRF5422BCZ bảng dữ liệu(HTML) 4 Page - Analog Devices |
|
4 / 13 page ![]() Data Sheet ADRF5422 SPECIFICATIONS analog.com Rev. 0 | 4 of 13 Table 1. Electrical Specifications (Continued) Parameter Symbol Test Conditions/Comments Min Typ Max Unit EN 33 µA RECOMMENDED OPERATING CONDITONS Positive Supply Voltage VDD 3.15 3.45 V Negative Supply Voltage VSS −3.45 −3.15 V Digital Control Input Voltage VCTRL 0 VDD V RF Input Power2, 3 PIN f = 250 MHz to 40 GHz and TCASE = 85°C Through Path RF signal is applied to the RFC or through connected RF1 and RF2 30 dBm Terminated Path RF signal is applied to unselected RF1 or unselected RF2 24 dBm Hot Switching RF signal is applied to the RFC while switching between RF1 and RF2 30 dBm Case Temperature TCASE −40 +105 °C 1 For input linearity performance over frequency, see Figure 2 and Figure 3. 2 For power derating over frequency, see Figure 2 and Figure 3. 3 For 105°C operation, the power handling degrades from the TCASE = 85°C specification by 3 dB. SINGLE-SUPPLY OPERATION VDD = 3.3 V, VSS = 0 V, VCTRL and VEN = 0 V or VDD, TCASE = 25°C, and 50 Ω system, unless otherwise noted. Table 2. Single-Supply Operation Specifications Parameter Symbol Test Conditions/Comments Min Typ Max Unit FREQUENCY RANGE f 0.1 55 GHz SWITCHING CHARACTERISTICS Rise Time and Fall Time tRISE and tFALL 10% to 90% of RFOUT 22 ns On Time and Off Time tON and tOFF 50% VCTRL to 90% of RFOUT 65 ns 0.1 dB RF Settling Time 50% VCTRL to 0.1 dB of final RFOUT 90 ns INPUT LINEARITY f = 250 MHz to 40 GHz 0.1 dB Power Compression P0.1dB 17 dBm Input Third-Order Intercept IIP3 Two-tone input power = 0 dBm each tone and Δf = 1 MHz 44 dBm RECOMMENDED OPERATING CONDITONS RF Input Power1, 2 PIN f = 250 MHz to 40 GHz and TCASE = 85°C Through Path RF signal is applied to the RFC or through connected RF1 and RF2 17 dBm Terminated Path RF signal is applied to unselected RF1 or unselected RF2 12 dBm Hot Switching RF signal is applied to the RFC while switching between RF1 and RF2 17 dBm 1 For power derating over frequency, see Figure 2 and Figure 3 . 2 For 105°C operation, the power handling degrades from the TCASE = 85°C specification by 3 dB. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |