| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ZSSC3154BA1C bảng dữ liệu(PDF) 14 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZSSC3154BA1C bảng dữ liệu(HTML) 14 Page - Renesas Technology Corp |
|
14 / 20 page ![]() ZSSC3154 Datasheet R36DS0046ED0160 Rev.1.50 Apr 19, 2024 Page 14 3.8.3 Analog-to-Digital Converter The analog-to-digital converter is implemented using the full differential switched-capacitor technique. The A/D resolution is 14-bit. The ADC operates in the second order configuration. The conversion is largely insensitive to short-term and long-term instabilities of the clock frequency. The ADC must be configured for the following features: ■ Adjustable A/D conversion time and integration phase length ■ Adjustable A/D conversion input voltage range Table 7. ADC Resolution versus Output Resolution and Sample Rate ADC Resolution rADC ADC Resolution Integration Phase Bridge Sensor Signal Sample Rate fOSC = Nominal Averaged Bandwidth fOSC = Nominal 14-bit 10-bit 0.60kHz 225Hz 9-bit 1.13kHz 425Hz 8-bit 2.03kHz 765Hz 7-bit 2.54kHz 955Hz 3.9 Signal Outputs 3.9.1 Analog Output ZSSC3154 provides two analog outputs at the AOUT1 and AOUT2 pins. The analog output behavior and the assignment of the several conditioned sensor signals to the analog outputs are configurable: ■ Conditioned bridge sensor signal is always assigned to and continuously output at the AOUT1 pin. ■ Conditioned temperature signal can be assigned to the analog output at the AOUT2 pin. ■ Conditioned half-bridge signal can be assigned to the analog output at the AOUT2 pin. ■ A function of the conditioned bridge sensor signal can be assigned to the analog output at the AOUT2 pin. ■ A sequential analog output mode can be assigned to the analog output at the AOUT2 pin. The sequence of output signals includes the diagnostic fault band HIGH and LOW level, the conditioned temperature or the half-bridge signal, and a function of the conditioned bridge sensor signal (refer to section 3.9.2). ■ Both analog outputs support low-pass filtering of the assigned conditioned sensor signals. ■ Both analog outputs can support diagnostic procedures of the application by providing a power-on diagnostic output waveform. For a detailed description of analog output modes and their configuration, refer to the ZSSC3154 Functional Description. 3.9.2 Sequential Analog Output The sequential analog output mode allows the analog output of two conditioned sensor signals at the AOUT2 pin. The sequence of output signals includes both the low and high diagnostic fault band levels (DFB Low and DFB High, respectively) for synchronization and for a repeated verification of diagnostic levels. This is followed by output of the conditioned temperature or half-bridge signal to provide the second signal. The last transmission in the sequence is a function of the conditioned bridge sensor signal for verification of the analog output at the AOUT1 pin. |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |