Back Button ADE9178GTL+T Datasheet HTML 76Page - Analog Devices ADE9178GTL+T Datasheet HTML 77Page - Analog Devices ADE9178GTL+T Datasheet HTML 78Page - Analog Devices ADE9178GTL+T Datasheet HTML 79Page - Analog Devices ADE9178GTL+T Datasheet HTML 80Page - Analog Devices ADE9178GTL+T Datasheet HTML 81Page - Analog Devices ADE9178GTL+T Datasheet HTML 82Page - Analog Devices ADE9178GTL+T Datasheet HTML 83Page - Analog Devices ADE9178GTL+T Datasheet HTML 84Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 80 / 122 page
background image
Data Sheet
ADE9178
REGISTER DETAILS: ADE9178
analog.com
Rev. A | 80 of 122
Table 34. ADE9178 Register Details (Continued)
Addr
Name
Bits
Bit Name
Settings
Description
Reset
Access
Synchronize RMSHALF
calculation with user-defined
half period value.
10
AUX4_RMSHALF_MODE_SEL
AUX4RMSHALF Mode
Selection. Set this
bit to calculate
AUX4RMSHALF based on
USER_PERIOD_HALF or
else synchronize with zero
crossings of AUX4 channel.
0x0
R/W
0
Synchronized with Zero
Crossing. Synchronize
RMSHALF calculation with
zero crossings of the channel.
1
Synchronized with User-
Defined Half Period Value.
Synchronize RMSHALF
calculation with user-defined
half period value.
9
AUX3_RMSHALF_MODE_SEL
AUX3RMSHALF Mode
Selection. Set this
bit to calculate
AUX3RMSHALF based on
USER_PERIOD_HALF or
else synchronize with zero
crossings of AUX3 channel.
0x0
R/W
0
Synchronized with Zero
Crossing. Synchronize
RMSHALF calculation with
zero crossings of the channel.
1
Synchronized with User-
Defined Half Period Value.
Synchronize RMSHALF
calculation with user-defined
half period value.
8
AUX2_RMSHALF_MODE_SEL
AUX2RMSHALF Mode
Selection. Set this
bit to calculate
AUX2RMSHALF based on
USER_PERIOD_HALF or
else synchronize with zero
crossings of AUX2 channel.
0x0
R/W
0
Synchronized with Zero
Crossing. Synchronize
RMSHALF calculation with
zero crossings of the channel.
1
Synchronized with User-
Defined Half Period Value.
Synchronize RMSHALF
calculation with user-defined
half period value.
7
AUX1_RMSHALF_MODE_SEL
AUX1RMSHALF Mode
Selection. Set this
bit to calculate
AUX1RMSHALF based on
0x0
R/W



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com