| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
E5EN-R3ML-500-N bảng dữ liệu(PDF) 15 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5EN-R3ML-500-N bảng dữ liệu(HTML) 15 Page - Omron Electronics LLC |
|
15 / 22 page ![]() Basic-type Digital Temperature Controller E5AN/E5EN 15 Operation Setting Levels Diagram This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and the conditions of use. Control stops when you move from the operation level to the initial setting level. Basic Type ✽1. You can return to the operation level by executing a software reset. ✽2. It is not possible to move to other levels from the calibration level by operating the keys on the front panel. It can be done only by first turning OFF the power. ✽3. From the manual control level, key operations can be used to move to the operation level only. ✽4. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN/E5EN). ✽5. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN/E5EN) Error Displays (Troubleshooting) When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below. Note: If the input value exceeds the display limit (-1999 to 9999), though it is within the control range, will be displayed under -1999 and above 9999. Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). ✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays. No.1 display Meaning Action Status at error Control output Alarm output s.err (S. Err) Input error ✽ Check the wiring of inputs for miswiring, disconnections, and short-circuits and check the input type. OFF Operates as above the upper limit. e333 (E333) A/D converter error Turn the power OFF then back ON again. If the display remains the same, the controller must be repaired. If the display is restored to normal, then a probable cause can be external noise affecting the control system. Check for external noise. OFF OFF e111 (E111) Memory error Turn the power OFF then back ON again. If the display remains the same, the controller must be repaired. If the display is restored to normal, then a probable cause can be external noise affecting the control system. Check for external noise. OFF OFF Start in manual mode. 25 100 c 25 100 c a-m Power ON ✽3 Manual mode Press the O Key or the PF Key for at least 1 s. ✽4 Press the O Key for at least 3 s while a-m is displayed. ( a-m will flash after 1st second.) Operation Level Press the O Key for at least 1 s. Press the O Key for at least 1 s. Input password. Input password while amoV is displayed. (Set value −169) Press the O Key less than 1 s. Press the O Key for at least 3 s. (Display will flash after 1st second.) Control stops. Press the O Key for less than 1 s. Press the O+ M Keys for at least 3 s. (Display will flash after 1st second.) Protect Level Control in progress Level change Not displayed for some models Control stopped Start in automatic mode. Adjustment Level PF Key ✽5 PF Key ✽5 Initial Setting Level Manual Control Level Monitor/Setting Item Level Advanced Function Setting Level Calibration Level Press the PF Key for at least 1 s. Communica- tions Setting Level Press the O+ M Keys for at least 1 s. ✽4 *1 Note: The time taken to move to the protect level can be adjusted by changing the “Move to protect level time” setting. ✽2 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |