| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SA2005MPA bảng dữ liệu(PDF) 3 Page - Sames |
|
|
|||||||||||||||||||||||||||||
SA2005MPA bảng dữ liệu(HTML) 3 Page - Sames |
|
3 / 12 page ![]() 3/12 sames sames SA2005M http://www.sames.co.za Figure 2: Pin connections: Package: DIP-24, SOIC-24 Part Number SA2005MPA SA2005MSA Package DIP-24 SOIC-24 ORDERING INFORMATION PIN DESCRIPTION Analog Ground. The voltage to this pin should be mid-way between V and V . DD SS Positive supply voltage. Typically +5V if a current transformer is used for current sensing. GND V DD Designation Description PIN 20 6 Negative supply voltage. Typically 0V if a current transformer is used for current sensing. V SS 18 Voltage sense inputs. The current into the A/D converter should be set at 14µA at nominal mains RMS voltage. The voltage sense input saturates at an input current of ±25µA peak. 21, 24, 3 IVN1, IVN2, IVN3 Inputs for current sensors. The termination resistor voltage from each current transformer is converted to a current of 16µA at rated conditions. The current sense input saturates at an input RMS current of ±25µA peak. 23, 22, 2, 1, 5, 4 IIN1, IIP1, IIN2, IIP2, IIN3, IIP3 This pin provides the connection for the reference current setting resistor. A 24kW resistor connected to V sets the optimum operating condition. SS 19 VREF Motor pulse outputs. These outputs can be used to drive an impulse counter or stepper motor directly. 11, 12 MON, MOP Multiplexed Phase or direction driver output. 13 Multiplexed LED drivers for direction and mains fail indication. 14, 15, 16 PH1, PH2, PH3 Calibration LED output. Refer to section LED Output (LED) for the pulse rate output options. 10 LED Test input. For normal operation connect this pin to V . SS 17 TEST 1 IIP2 IVN2 GND IIN2 IIN1 VREF IVN3 IIP1 VSS IIP3 IIN3 VDD RA RE IVN1 TEST PH3 PH2 PH1 PH / DIR LED MON MOP IM 2 3 4 5 6 19 18 17 16 15 14 13 10 11 12 9 8 7 20 21 22 23 24 dr-01617 PH / DIR Rated conditions select input. 7 RA The RE input selects the calibration LED resolution as well as the summing mode for the programmable adder. 8 RE The IM inputs selects the counter resolution (Motor drive output). 9 IM |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |