| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
405C bảng dữ liệu(PDF) 2 Page - Automatic Timing & Controls, Inc. |
|
|
|||||||||||||||||||||||||||||
405C bảng dữ liệu(HTML) 2 Page - Automatic Timing & Controls, Inc. |
|
2 / 3 page ![]() 37 SPECIFICATIONS MODELS 405C100F1X ON-Delay w/instantaneous & delayed relays (1 or 10 SEC/MIN/HRS) 405C500F1X ON-Delay w/instantaneous & delayed relays (5 or 50 SEC/MIN/HRS) 405C100F2X ON-Delay/Interval with (1) DPDT relay (1 or 10 SEC/MIN/HRS) 405C500F2X ON-Delay/Interval with (1) DPDT relay (5 or 50 SEC/MIN/HRS) Both models available in 6 ranges from 1 SEC to 10 HRS or 5 SEC to 50 HRS CONTACT Rated 10 AMPS resistive at 30 VDC or 250 VAC (or less) RATING 1/8 HP @120 VAC 1/4 HP @ 240 VAC 240 VA @ 240 VAC LIFE: 10 million operation with no load 100,000 operations with: 10 AMPS at 30 VDC (or less) or 10 AMPS at 250 VAC (or less) CONTACT Silver Nickel MATERIAL TEMPERATURE 0 to 122°F (-18 C to 50 C) RATING MOUNTING Plug-in octal base; mounts in any position w/ retaining clip Options: Surface mounting socket DIN rail mounting socket Panel-mounting adapter kit Plug-on socket kit POWER Universal power supply - reverse polarity protected REQUIREMENTS Unit will accept power from 24 to 240 VAC, 50 or 60 Hz, (+10%, - 20%) AC Inrush - 1.5 Amps Power required - 1.2 watts DC Maximum ripple @100 Hz - 5% Current required - 50mA Power required - 1.2 watts F option Peak inrush current = 2 AMPS @ 24 VDC N option Peak inrush current = 150 mA @ 24 VDC REPEAT Varies as a function of temperature. ACCURACY Any voltage (constant temperature): ±0.5%* Any voltage (0°F to 140°F): ±2.0%* *Variation from average actual time. MINIMUM SETTING 2% of range, with the exception of 50 mSEC on the 1 second range SETTING ACCURACY ± 5% of range RESET a 0 to 20 mSEC power interruption: guaranteed no reset. b 20 to 65 mSEC; it may reset (40 mSEC typical reset). c Over 65 mSEC guaranteed to reset. The TDR will reset properly and not start timing when subjected to an open start switch leakage of 1.5 mA or less. (Prox switch and Triac drive applications) WEIGHT 5 oz. (140 g) WIRING WIRING MODEL 405C...F1X MODEL 405C...F2X TERMINAL WIRING MODEL NUMBER MODEL NUMBER 405C RANGE Six dial-selected ranges 100 (1 or 10 SEC/MIN/HRS) Six dial-selected ranges 500 (5 or 50 SEC/MIN/HRS) VOLTAGE & FREQUENCY 12 VDC E 24 to 240 VAC (50/60 Hz) F and 24 VDC 24 VDC (low inrush N current for short-circuit protected sensors) ARRANGEMENT 8-Pin ON-Delay (with instantaneous contacts) 1 Timing Mode 8-pin ON-Delay, 2 Interval Timing Modes FEATURES Standard X Special K ACCESSORIES 8-Pin surface/DIN rail socket 000-825-85-00 Hold down for above socket 407-025-13-00 (Requires 2 per unit) Panel mounting bracket 405-320-02-00 Plug-in socket kit (8-pin) 319-261-45-00 8-Pin panel socket 000-825-90-00 w/rear facing terminals Automatic Timing & Controls 800.727.5646 atcdiversified.com Automatic Timing & Controls 800.727.5646 atcdiversified.com |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |