| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
G3PC bảng dữ liệu(PDF) 6 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
G3PC bảng dữ liệu(HTML) 6 Page - Omron Electronics LLC |
|
6 / 6 page ![]() J-76 SSR with Failure Detection Function G3PC Precautions Refer to the Technical Information for SSRs (Cat. No. J137) for gen- eral precautions. I Correct Use Before Actual Operation 1. In actual operation, the G3PC may cause accidents that were unforeseeable at the theoretical stage. Therefore it is necessary to test the G3PC under a variety of conditions that are possible. As for the characteristics of the G3PC, it is necessary to consider the differences between G3PC Units. 2. The ratings in this datasheet are for testing in a temperature range of 15 to 30 °C, a relative humidity range of 25% to 85%, and an atmospheric pressure range of 88 to 106 kPa. When testing operation, it is necessary to confirm correct operation not only with the actual load that will be used, but also at the same ambi- ent conditions as for actual operation. Mounting Method DIN Track Mounting When mounting to a DIN track, mount the G3PC until it clicks into place, otherwise it become loose during use and fall. Fix both ends with end plates. Panel Mounting When mounting directly to a panel, observe the following conditions: Screw diameter: M4 Tightening torque: 0.98 to 1.47 N·m Note: Use the G3PC at a load current of 50% of the rated load current when it is mounted horizontally. Side-by-side Mounting Note: Use the G3PC at a load current of 80% of the rated load current when it is mounted side-by-side. Wiring • When using crimp terminals, observe the terminal clearances shown below. • Be sure that all lead wires are of a thickness appropriate for the current. • The output terminals are charged, and touching them may result in electric shock, even when the G3PC is OFF. Separate the outputs from the power supply by installing a circuit-breaker at a higher level in the circuit. Tightening Torque Be sure to tighten the screws to the specified torques given below. Not doing so may result in malfunction. Horizontal Mounting Vertical Mounting Panel Panel 5 mm Wiring duct 80 mm min. 80 mm min. Wiring duct Terminal number Screw terminal diameter Tightening torque A1, A2, X1, X2 M3.5 0.59 to 1.18 N·m 1/L1, 2/T1, 3 M4 0.98 to 1.47 N·m 10 7.0 12.4 10 M3.5 Main Circuit Power Supply (Terminals 1 to 3) Operating Input/Alarm Output (Terminals A1, A2, X1, and X2) In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J127-E1-02 |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |