Back Button HT9480 Datasheet HTML 10Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 11Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 12Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 13Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 14Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 15Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 16Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 17Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 18Page - Holtek Semiconductor Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 47 page
background image
HT9480
Rev. 1.20
14
July 31, 2002
If crystal mask option is selected, the MCU clock can be
fed by X1, X2 decoder input clock (See Application Cir-
cuit 2).
The functional units chip reset status is shown in the fol-
lowing table.
PC
0000H
Interrupt
Disabled
Prescaler
Cleared
WDT
Cleared. After master reset,
WDT starts counting.
Programmable timer
Counter
Off
Timer/event Counter
Off
Programmable Tone
Generator
Off
Pager Decoder
Off
Input/output Ports
input mode
SP
Points to the top of the stack
Programmable timer counter and timer/event coun-
ter
The programmable timer counter (TMR0) and
timer/event counter (TMR1) are constructed using the
same structure. Both counters contain an 8bit program-
mable count-up counter, whose clocks may come from
an external source or from the system clock divided by
4.
If the internal instruction clock is selected, only one ref-
erence time-base is provided. The external clock input
allows the user to count external events, measure time
intervals or pulse widths, or generate an accurate time
base. The clock of the programmable timer counter
should come from the external clock of the 75Hz for
Real Time Clock (RTC) if a 76.8kHz crystal is used.
There are two sets of registers related to the program-
mable timer counter and to the timer/event counter
namely, TMR0 (0DH) and TMRC0 (0EH) and TMR1
(10H) and TMRC1 (11H). There are also two physical
registers mapped to the TMR0 and TMR1 locations:
Writing to TMR0 and TMR1 puts the starting value in the
programmable timer counter and in the timer/event
counter preload registers, while reading them gets the
contents of the two counters. TMRC0 and TMRC1 are
control registers used to define some timer options.
The TM0 and TM1 bits define the operation mode. The
event count mode is used to count external events,
which means that the clock source may come from ei-
ther a 256Hz generator (for TMR0) or an external pin
(for TMR1). The timer mode functions as a normal timer,
with the clock source coming from the instruction clock
or from the outputs of the TMR1 prescaler (TMR0 can-
not be used in this mode). The pulse width measure-
ment mode can be used to count the high or low level
duration of the external signal TMR1, TMR0 is also dis-
abled in this mode. The counting is based on the system
clock.
In the event count or timer mode, once the programma-
ble timer counter or timer/event counter starts counting,
it will count from the current contents in the counter to
FFH. Once an overflow occurs, the counter is reloaded
from its counter preload register and generates an inter-
rupt request flag (T0F; bit 5 of INTC and T1F; bit 6 of
INTC for programmable timer counter and timer/event
counter, respectively).
W D T
H A L T
W D T
T i m e - o u t
R e s e t
R E S
C o l d
R e s e t
W a r m R e s e t
Reset configuration
Labels
(TMRC0 and TMRC1)
Bits
Function
¾
0~2
Unused bit, read as
²0²
TE
3
To define the TMR0 and TMR1 active edge of programmable timer counter and
timer/event counter (0=active on low to high; 1=active on high to low)
TON
4
To enable/disable timer counting (0=disabled; 1=enabled)
¾
5
Unused bits, read as
²0²
TM0
TM1
6
7
To define the operation mode
01=Event count mode (external clock)
10=Timer mode (internal clock)
11=Pulse width measurement mode
00=Unused
TMRC register



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com