| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TCN75AVOA bảng dữ liệu(PDF) 22 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
TCN75AVOA bảng dữ liệu(HTML) 22 Page - Microchip Technology |
|
22 / 32 page ![]() TCN75A DS21935C-page 22 © 2006 Microchip Technology Inc. 5.3.4.6 Fault Queue The fault queue feature can be used as a filter to lessen the probability of spurious activation of the ALERT pin. TA must remain above TSET for the consecutive num- ber of conversion cycles selected using the Fault Queue bits. Bit 3 and bit 4 of CONFIG can be used to select up to six fault queue cycles. For example, if six fault queues are selected, TA must be greater than TSET for six consecutive conversions before ALERT is asserted as a comparator or an interrupt output. This queue setting also applies for THYST. If six fault queues are selected, TA must remain below THYST for six consecutive conversions before ALERT is deas- serted (Comparator mode) or before another interrupt is asserted (Interrupt mode). 5.3.4.7 ΣΔ ADC Resolution The TCN75A provides access to select the ADC resolution from 9-bit to 12-bit (0.5°C to 0.0625°C resolution) using bit 6 and bit 5 of the CONFIG register. The user can gain better insight into the trends and characteristics of the ambient temperature by using a finer resolution. Increasing the resolution also reduces the quantization error. Figure 2-3 shows accuracy versus resolution. Table 5-1 shows the TA register conversion time for the corresponding resolution. TABLE 5-1: RESOLUTION AND CONVERSION TIME 5.4 Summary of Power-up Condition The TCN75A has an internal Power-on Reset (POR) circuit. If the power supply voltage VDD glitches down to the 1.7V (typ.) threshold, the device resets the registers to the power-up default settings. Table 5-2 shows the power-up default summary. TABLE 5-2: POWER-UP DEFAULTS At power-up, the TCN75A has an inherent 2 ms (typ.) power-up delay before updating the registers with default values and start a conversion cycle. This delay reduces register corruption due to unsettled power. After power-up, it takes tCONV for the TCN75A to update the TA register with valid temperature data. Bits Resolution tCONV (typ.) 9 0.5 30 ms 10 0.25 60 ms 11 0.125 120 ms 12 0.0625 240 ms Register Data (Hex) Power-up Defaults TA 0000 0°C TSET A000 80°C THYST 9600 75°C Pointer 00 Temperature register CONFIG 00 Continuous Conversion Comparator mode Active-low Output Fault Queue 1 9-bit Resolution |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |