| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
PS501 bảng dữ liệu(PDF) 7 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PS501 bảng dữ liệu(HTML) 7 Page - Microchip Technology |
|
7 / 42 page ![]() 2004 Microchip Technology Inc. DS21818C-page 7 PS501 Figure 2-2 shows the relationship of the COVPack and CFVPack values. FIGURE 2-2: COVPack AND CFVPack VALUE RELATIONSHIP In-circuit calibration of the voltage is done at the time of manufacture to obtain absolute accuracy in addition to high resolution. Individual cell voltage measurements can be accurate to within ±20 mV. The individual cell voltage inputs are also calibrated the same way the pack voltage is. There is one offset value, COVCell, for all individual cells and up to four different correction factors, CFVCell1 through CFVCell4, one for each cell input. 2.5 Temperature Measurements The A/D receives input from the internal temperature sensor to measure the temperature. Optionally, an external thermistor can be connected to the VNTC pin which is also monitored by the A/D converter. An output reference voltage for use with an external thermistor is provided on the VREFT pin. The A/D uses an 11-bit resolution mode for the temperature measurements. A standard 10 kOhms at 25°C Negative-Temperature- Coefficient (NTC) device of the 103ETB type is suggested for the optional external thermistor. One leg of the NTC should be connected to the VREFT pin and the other to both the VNTC pin and a 3.65 kOhms resis- tor to analog ground (VSSA). The resistor forms the lower leg of a voltage divider circuit. To maintain high accuracy in temperature measurements, a 1% resistor should be used. A look-up table is used to convert the voltage measure- ment seen at the VNTC pin to a temperature value. The external thermistor should be placed as close as possi- ble to the battery cells and should be isolated from any other sources of heat that may affect its operation. Calibration of the temperature measurements involves a correction factor and an offset exactly like the current and voltage measurements. The internal temperature measurement makes use of correction factor CFTempI and offset COTempI, while the VNTC and VREFT pins for the optional external thermistor make use of correction factor CFTempE and offset COTempE. Ideal A/D Response Actual A/D Response CFVPack COVPack Raw Measurement Actual Voltage |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |