44 / 75 page ![]() 3.3.4.4 Burst mode exit control The burst mode exit control supports a smooth switch-over for the closed feedback control loop when leaving burst mode due to load jump or load is slowly increasing beyond a burst mode exit current set-point threshold. There are two burst mode exit paths supported. A strong load jump requires a fast burst mode exit (see Chapter 3.3.4.4.2) and immediate full power delivery whereas a slightly increasing load shall be controlled for a smooth switch-over (see Chapter 3.3.4.4.1) for the feedback voltage control in order to avoid oscillations at the output. A smaller load jump that leads to a fast burst mode exit shall also not lead to oscillations at the output. Both requirements are covered by introducing an offset ΔVFBBM<x>exoffs on the measured feedback voltage VFB, when determining the correlated internal current set-point ISET% based on the output current control law (see Chapter 3.3.1.3). Once tracking mode is entered (CRM or continuous ZV-RVS mode operation) ΔVFBBM<x>exoffs is linearly reduced by every half-bridge switching cycle (see Figure 39). Tracking Mode BM entry ISET%(VFB)< ISETBMen% no yes Decreasing offset ΔVFBBM<x>exoffs Sleep phase Wake-up VFB > VFBBMctrl Fast BM exit VFB > VFBBMfastex no yes ZV-RVS pulse Switch-over control law Slow BMexit ISET%(VFB)> ISETBMex% yes Sleep phase VFB < VFBBMctrl yes no Add offset ΔVFBBMslwexoffs to sensed VFB yes Switch-over control law no no Burst mode operation Continuous mode operation Figure 39 Burst mode exit flow diagram During burst mode operation the feedback control law only contains two thresholds at FB pin and one for the internal current set-point ISET% (see Figure 40): • VFBBMctrl for controlling the burst on-frame and the sleeping phase • VFBBMfastex for immediately leaving the burst mode • ISETBMex% based on output current estimation for slowly leaving the burst mode When a burst mode exit condition is met a switch-over of the output current control law is taking place. The feedback voltage level corresponds at that point of time to a different current set-point compared to steady state continuous operation. E.g. if a slow burst mode exit takes place with ISET%(VFB) > ISETBMex%, the feedback XDP Hybrid-flyback Controller XDPS2201 Functional description Datasheet 44 R1.2 2021-06-10 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |