công cụ tìm kiếm bảng dữ liệu linh kiện điện tử
  Vietnamese  ▼
ALLDATASHEET.VN

X  

CPT-DINAV63LS2AX bảng dữ liệu(PDF) 3 Page - List of Unclassifed Manufacturers

tên linh kiện CPT-DINAV63LS2AX
Giải thích chi tiết về linh kiện  Energy Management Compact Power Transducer
PDF  13 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
nhà sản xuất  ETC2 [List of Unclassifed Manufacturers]
Trang chủ  
Logo ETC2 - List of Unclassifed Manufacturers

CPT-DINAV63LS2AX bảng dữ liệu(HTML) 3 Page - List of Unclassifed Manufacturers

  CPT-DINAV63LS2AX Datasheet HTML 1Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 2Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 3Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 4Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 5Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 6Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 7Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 8Page - List of Unclassifed Manufacturers CPT-DINAV63LS2AX Datasheet HTML 9Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 13 page
background image
Specifications are subject to change without notice
CPT-DINADS110706
3
CPT-DIN
CptASoft software: parameter programming and data reading
Filtering parameters
Alarm variables
Alarm set-points and rele-
vant parameters
Variables to be connected
to the analogue outputs
Scaling of analogue outputs
Energies to be connected
to the pulse outputs
Parameters related to the
pulse outputs
Reset function: max/min
values, energies, dmd
Data access
By means of RS232 serial
port, RS485 serial port or RS232
configuration port (RJ12)
CptASoft
Multi language software to
program the working
parameters of the transducer
and to read the energies and
the instantaneous variables.
Compatibility with Windows
95/98/98SE/2000/XP.
Working mode
Two different working
modes can be selected:
- management of a local
RS485 network;
- management of the
communication from single
instrument to PC (RS232);
Programming parameters
System selection: 1-2-3
phases
CT/VT ratios
RS422/RS485
(on request)
Multidrop
bidirectional (static and
dynamic variables)
Connections
2 or 4 wires, max. distance
1200m, termination directly
on the instrument
Addresses
From 1 to 255,
selectable via software
Protocol
MODBUS/JBUS (RTU)
Data (bidirectional)
Dynamic (reading only)
System and phase variables:
see table “List of variables...”
Static (writing only)
All the configuration parameters.
Data format
1 start bit, 8 data bit,
no parity,1 stop bit
Baud-rate
4800, 9600,
19200, 38400 bits/s
Insulation
By means of optocouplers,
See table “Insulation
between inputs and outputs”
RS232
Halfduplex communication
Type
Point to point connection
Connections
3-wire, max. distance 15m
Address
1 to 255 selectable via software
Protocol
MODBUS/JBUS (RTU)
Baud-rate
4800, 9600, 19200,
38400 bits/s
other characteristics like
R422/RS485 port
Dupline
Bus
Full Dupline compatibility
Address
Programmable using CptASoft
Variables
kWh, kvarh + 8 variables
chosen among the
available ones.
Insulation
By means of optocouplers.
See table “Insulation
between inputs and outputs”
Output Specifications (cont.)
Connections
RJ12 (3-wire) for special cable
Baud-rate
4800 bits/s
Data format
1 start bit, 8 data bit,
no parity, 1 stop bit
Insulation
By means of optocouplers,
See table “Insulation
between inputs and outputs”
RS232 Configuration Bus
Transformer ratio
CT
1 to 60 000
VT (PT)
1.0 to 6 000.0
Filter
Operating range
0 to 100% of the
retransmitted scale
Filtering coefficient
1 to 32
Filter action
Measurements, alarms,
serial output
(fundamental variables: V, A,
W and their derived ones).
System selection
System 3, unbalanced
3-phase (3-wire, 4-wire)
3-phase ARON
2-phase (3-wire)
System 3, balanced
1-phase (2-wire)
3-phase (3-wire, 4-wire)
3-phase (3-wire) “1CT+1VT”
3-phase (3-wire) “1CT+3VT”
System 1, balanced
3-phase (4-wire) “1CT+1VT”
3-phase (4-wire), phase to
neutral voltage measurement
1-phase (2-wire)
Software functions



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


bảng dữ liệu tải về

Go To PDF Page


Link URL



Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không?  [ DONATE ] 

Alldatasheet là   |   Quảng cáo   |   Liên lạc với chúng tôi   |   Chính sách bảo mật   |   Liên kết đến bảng dữ liệu    |   Trao đổi link   |   Tìm kiếm theo nhà sản xuất
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com