| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
EPR-9 bảng dữ liệu(PDF) 2 Page - Power Integrations, Inc. |
|
|
|||||||||||||||||||||||||||||
EPR-9 bảng dữ liệu(HTML) 2 Page - Power Integrations, Inc. |
|
2 / 32 page ![]() 5 W Universal Input Dual Output Isolated TNY266 03-April-2001 Table Of Contents 1 Introduction .................................................................................................................3 2 Power Supply Requirements Specification .............. ...................................................3 3 Schematic ...................................................................................................................4 3.1 Configuration “1” 2 kV..........................................................................................4 3.2 Configuration “2” 6 kV..........................................................................................5 4 Circuit Description.......................................................................................................6 5 Layout and Picture......................................................................................................7 6 Bill Of Materials...........................................................................................................9 6.1 Configuration ”1”, 2 kV.........................................................................................9 6.2 Configuration ”2”, 6 kV.........................................................................................9 7 Transformer – T1 ......................................................................................................10 7.1 Transformer Drawing .........................................................................................10 7.2 Electrical Specifications .....................................................................................10 7.3 Transformer Construction ..................................................................................10 7.4 Transformer Materials........................................................................................11 7.5 Transformer Winding Instructions......................................................................11 7.6 Transformer Bobbin Dimensions .......................................................................12 7.7 Transformer Spreadsheet..................................................................................13 8 Performance Data.....................................................................................................15 8.1 Efficiency ...........................................................................................................15 8.2 Regulation @ 25 °C Ambient.............................................................................16 8.3 Temperature ......................................................................................................17 8.4 Waveforms (2 kV config.”1”) ..............................................................................18 8.4.1 Turn-on Delay/Hold-up Time ......................................................................18 8.4.2 Auto-Restart ...............................................................................................19 8.5 Transient Response...........................................................................................21 8.6 Conducted EMI Scans .......................................................................................22 8.7 Surge Voltage Immunity (2 kV and 6 kV, 1.2/50 µs per IEC1000-4-5)...............23 8.8 Acoustic Emissions............................................................................................24 Appendix A Example of 24 V Output Design....................................................................25 Appendix A1.1 Schematic of 24 V Design....................................................................25 Appendix A1.2 Bill of Materials (5 W, 5 VDC, 24 VDC PS)..............................................26 Appendix A1.3 Transformer Spreadsheet ....................................................................27 9 Revision History........................................................................................................29 Important Note: Although the EP-9 is designed to satisfy safety isolation requirements, the engineering prototype has not been agency approved. Therefore all testing should be performed using an isolation transformer to provide the AC input to the prototype board. Page 2 of 32 Power Integrations, Inc. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |