| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
RT7204E bảng dữ liệu(PDF) 33 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT7204E bảng dữ liệu(HTML) 33 Page - Richtek Technology Corporation |
|
33 / 45 page ![]() F RT7204E Copyright © 2024 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. RT7204E_DS-00 May 2024 www.richtek.com 33 16 Application Information (Note 8) 16.1 Constant Voltage (CV) Loop As shown in Figure 7, the RT7204E integrates two error amplifiers (EA), which are connected with the feedback compensators to regulate the output voltage and current, respectively. The output voltage is determined by the following equation: VOUT = KFB x VREF_CV where KFB = (RFB1 + RFB2) / RFB2 = 10 Therefore, the VOUT is determined by VREF_CV, the analog output from the DAC, which is controlled by MCU. 16.2 Constant Current (CC) Loop As shown in Figure 7, the RT7204E integrates a virtually zero input offset high-side current-sense amplifier with differential mode inputs to minimize noise interference. The sensed signal, Io_signal, is fed into an 11-bit ADC for monitoring and processing by the MCU. The reference voltage of the CC loop is determined by VREF_CC (from the DAC), which is programmed according to the requirements of charger. Both the constant voltage and the constant current compensation loops are connected to the OPTO pin. The OPTO driver sinks current through an external resistor RD and an optocoupler that isolates the secondary side from the primary side, and then feedbacks the compensation signal to the primary side. Note that for better linearity of the loop compensation range, RD should be designed to cover the operation at the minimum output voltage. −− OUT_MIN F COMP_MAX D (V V 0.3V) CTR I R where CTR: Current transfer ratio of the optocoupler VF: Forward voltage of the optocoupler 0.3V: The minimum OPTO voltage for the OPTO driver to sink the minimum OPTO sink current ICOMP_MAX: The maximum COMP sourcing current of a traditional PWM controller in the primary side. It is a current sourced from an internal bias through a built-in pull-up resistor connected to the COMP pin in the PWM controller. |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |