| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
SP7662 bảng dữ liệu(PDF) 7 Page - Sipex Corporation |
|
|
|||||||||||||||||||||||||||||
SP7662 bảng dữ liệu(HTML) 7 Page - Sipex Corporation |
|
7 / 19 page ![]() 7 Mar -07 Rev AJ SP7662 Wide Input Voltage Range 2A, 300kHz Buck Regulator © 2007 Sipex Corporation THEORY OF OPERATION Therefore without external biasing the ViN start threshold is 9.5V. A small capacitor mayberequiredbetweenUVINandGNDto filteroutnoise.ForapplicationswithViN of 5V or 3.3V, connect UVIN directly to ViN. To program the ViN start threshold, use a pair of external resistors as shown. If external resistors are an order of magnitude smaller than internal resistors, then the ViN start thresholdisgivenby: ViN(start) = 2.5 • (R6+R7)/R7 For example, if it is required to have a ViN startthresholdof7V,thenletR7=5KΩand using the ViN start threshold equation we get R6=9.09KΩ. Thermal and Short-Circuit Protection Because the SP7662 is designed to drive largeoutputcurrent,thereisachancethatthe power converter will become too hot. There- fore, an internal thermal shutdown (45°C) has been included to prevent the IC from malfunctioning at extreme temperatures. A short-circuit detection comparator has also been included in the SP7662 to protect against an accidental short at the output of the power converter. This comparator con- stantly monitors the positive and negative terminals ofthe error amplifier,and ifthe VfB pin falls more than 250mV (typical) below the positive reference, a short-circuit fault is set. Because the SS pin overrides the internal 0.8V reference during soft start, the SP7662 is capable of detecting short-circuit faults throughout the duration of soft start as well as in regular operation. Over-Current Protection The Over-current protection feature can onlybeusedonoutputvoltages≤3.3volts. It is limited by the common mode rating of the op-amp used to sense the voltage across the inductor. Over-current is de- tected by monitoring a differential voltage across the output inductor as shown in the nextfigure. ISN SP7662 SWN ISP VOUT L=2.7uH,DCR=4.1mΩ R3 5.11KΩ R4 5.11KΩ CS 0.uF CSP 6.8nF Over-current detection circuit Inputs to an over-current detection com- parator, set to trigger at 60 mV nominal, are connected to the inductor as shown. Since the average voltage sensed by the com- parator is equal to the product of inductor current and inductor DC resistance (DCR), then IMAx = 60mV / DCR. Solving this equa- tionforthespecificinductorincircuit1,IMAx = 4.6A. When IMAx is reached, a 220 ms time-out is initiated, during which top and bottom drivers are turned off. Following the time-out, a restart is attempted. If the fault condition persists, then the time-out is re- peated (referred to as hiccup). Increasing the Current Limit If it is desired to set IMAx > {60mV / DCR} (in this case larger than 4.6A), then a resistor R9 should be added as shown in the next figure.R9formsaresistordividerandre- duces the voltage seen by the comparator. Since:60mV (IMAx • DCR) R9 = {R3 + R4 + R9} |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |