| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
BL20-2DO-R-NC bảng dữ liệu(PDF) 1 Page - Turck, Inc. |
|
|
|||||||||||||||||||||||||||||
BL20-2DO-R-NC bảng dữ liệu(HTML) 1 Page - Turck, Inc. |
|
1 / 2 page ![]() Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com1 / 2 BL20 electronic module Relay Module, 2 × Normally Closed BL20-2DO-R-NC Type BL20-2DO-R-NC ID 6827028 Number of channels 2, NC contacts Rated voltage from the supply terminal 24 VDC Nominal current from field supply ð 20 mA Nominal current from module bus ð 28 mA Power dissipation, typical ð 1 W Output connectivity Screw, tension spring Outputs Load type resistive, inductive, lamp load Rated load voltage 230/30 VAC/DC Simultaneity factor 1 Useful lifetime at 230 VAC, 5 A 100000 Useful lifetime at 230 VAC, 0.5 A 1000000 Output current with DC voltage (resistive) see load limit curve Electrical isolation electronics for the field level Dimensions (W x L x H) 12.6 x 74.1 x 55.4 mm Approvals CE, cULus, zone 2, Class I, Div. 2 Ambient temperature 0…+55 °C Storage temperature -25…+85 °C Relative humidity 15…95 %, no condensation allowed Vibration test Acc. to EN 61131 Shock test Acc. to IEC 60068-2-27 Drop and topple acc. to IEC 68-2-31 and free fall to IEC 68-2-32 Electromagnetic compatibility Acc. to EN 50082-2 Protection class IP20 ■ Fieldbus and connection technology inde- pendent ■ Protection class IP20 ■ LEDs indicate status and diagnostic ■ Electronics galvanically separated from the field level via optocouplers ■ 2 NC channels Functional principle BL20 electronic modules are plugged into the purely passive base modules which are used for connection of field devices. Maintenance is significantly facilitated due to separation of the connection level from the module electronics. Furthermore flexibility is enhanced because the base modules provide a choice of tension spring or screw connection technology. The electronic modules are completely inde- pendent of the type of higher level field bus through the use of gateways. Load limit curve Definition: At 1000 switching cycles, a stand- ing electric arc of > 10 ms may not occur. |
Số phần tương tự - BL20-2DO-R-NC |
|
Mô tả tương tự - BL20-2DO-R-NC |
|
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |