| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MXM5 bảng dữ liệu(PDF) 2 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
MXM5 bảng dữ liệu(HTML) 2 Page - Sensata Technologies, Inc. |
|
2 / 4 page ![]() www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. Interface ISO 11898 Transmission Rate Max 12 MBauds Device Addressing By Rotary Switches Power Supply 10 – 30Vdc Current Consumption Max 100mA (24Vdc) Power Consumption Max 2,5W Step Frequency LSB 800 kHz Accuracy + ½ LSB EMC EN 61000-6-4 EN 61000-6-2 Electrical Lifetime > 105 h The Profibus-DP interface supports CLASS 1 and CLASS 2 functionality according to the encoder profile. In addition to these functions the GSD-file supports further features, for example software limit switches. Further more, the following encoder parameters can be programmed directly via the Profibus-DP network without any extra device. Counting Direction This parameter counting direction defines whether the output code increases or decreases when the shaft rotates clockwise Resolution (Positions per Turns) The parameter ‘resolution per revolution’ is used to program the desired number of steps per revolution. Each value between 1 and the physical resolution per revolution can be programmed Total Resolution “Max-RANGE“ This parameter is used to program the desired number of measuring units over the total measuring range. This value may not exceed the total physical resolution of the absolute rotary encoder Reset (RAX) The preset value is the desired position value, which should be reached at a certain physical position of the axis. The position value is set to the desired process value by the parameter preset Velocity The implemented software can additionally deliver the current velocity. This value is transmitted in binary code, 16 Bit, in addition to the process value. It is possible to choose between four different units: steps per 10 ms, per 100 ms, per 1000 ms and revolutions per minute Software Limit Switches Function Two software limit switches can be set. If the position value falls below the lower or exceeds the higher limit switch, a status bit in the process value is set Teach-In (Online Parameterization) A special mode is available for commissioning phase of the device. This makes it possible to change parameters while the encoder is in data exchange mode ELECTRICAL SPECIFICATIONS PROGRAMMABLE PARAMETERS |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |