| công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
AFEX82H1 bảng dữ liệu(PDF) 78 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AFEX82H1 bảng dữ liệu(HTML) 78 Page - Texas Instruments |
|
78 / 115 page ![]() 7.1.14 FIFO_CFG Register (Offset = Fh) [Reset = 00F0h] Return to the Register Map. Table 7-16. FIFO_CFG Register Field Descriptions Bit Field Type Reset Description 15-10 RESERVED R 0h 9 FIFO_H2U_FLUSH WSC 0h Flush HART-to-µC FIFO (FIFO_H2U) Clear the pointers for the FIFO_H2U. 8 FIFO_U2H_FLUSH WSC 0h Flush µC-to-HART FIFO (FIFO_U2H) Clear the pointers for the FIFO_U2H. 7-4 H2U_LEVEL_SET R/W Fh FIFO_H2U FIFO Level Flag Trip Set Sets the level for FIFO_H2U at which the Level Flag trips. This is a (>) comparison. Because the FIFO size is 5 bits wide, the LSB is not used with this 4-bit setting. Only change this field while MODEM_CFG.HART_EN = 0. 3-0 U2H_LEVEL_SET R/W 0h FIFO_U2H FIFO Level Flag Trip Set Sets the level for FIFO_U2H at which the Level Flag trips. This is a (<) comparison. Because the FIFO size is 5 bits wide, the LSB is not used with this 4-bit setting. Only change this field while MODEM_CFG.HART_EN = 0. 7.1.15 ALARM_ACT Register (Offset = 10h) [Reset = 8020h] Return to the Register Map. Table 7-17. ALARM_ACT Register Field Descriptions Bit Field Type Reset Description 15-14 SD_FLT R/W 2h Self-Diagnostic Fault Action These bits set the device action after a self-diagnostic fault. 0h = No Action 1h = Set DAC to CLEAR state 2h = Switch to alarm voltage determined by ALMV_POL (default) 3h = Place DAC into Hi-Z (power-down) 13-12 TEMP_FLT R/W 0h TEMP Fault Action These bits set the device action if the ADC temperature is outside the TEMP_THRESHOLD Hi or Lo thresholds. 0h through 3h = Same as SD_FLT field (default 0h) 11-10 AIN1_FLT R/W 0h AIN1 Fault Action These bits set the device action if the ADC AIN1 channel is outside the AIN1_THRESHOLD Hi or Lo thresholds. 0h through 3h = Same as SD_FLT field (default 0h) 9-8 AIN0_FLT R/W 0h AIN0 Fault Action These bits set the device action if the ADC AIN0 channel is outside the AIN0_THRESHOLD Hi or Lo thresholds. 0h through 3h = Same as SD_FLT field (default 0h) 7-6 CRC_WDT_FLT R/W 0h CRC and WDT Fault Action These bits set the device action when a SPI CRC or SPI Watchdog Timeout error occurs. 0h through 3h = Same as SD_FLT field (default 0h) 5-4 VREF_FLT R/W 2h VREF Fault Action These bits set the device action when a fault is detected on VREF. 0h through 3h = Same as SD_FLT field a 3-2 THERM_ERR_FLT R/W 0h Thermal Error Fault Action These bits set the device action when a high temperature error occurs (> 130°C). 0h through 3h = Same as SD_FLT field (default 0h) 1-0 THERM_WARN_FLT R/W 0h Thermal Warning Fault Action These bits set the device action when a high temperature warning occurs (> 85°C). 0h through 3h = Same as SD_FLT field (default 0h) AFE782H1, AFE882H1 SLASF43 – DECEMBER 2023 www.ti.com 78 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: AFE782H1 AFE882H1 |
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |