2 / 3 page ![]() Technical data Measurement performance Relative humidity Measurement range 0–100 %RH Accuracy (incl. non-linearity, hysteresis, and repeatability): at 0 … +40 °C (+32 … +104 °F) ±1.5 %RH (0–90 %RH) ±2.5 %RH (90–100 %RH) at −40 … 0 °C (−40 … +32 °F) and +40 … +60 °C (+104 … +140 °F) ±3.0 %RH (0–90 %RH) ±4.0 %RH (90–100 %RH) Factory calibration uncertainty at +20 °C (+68 °F): ±1.1 %RH (0–90 %RH) ±1.8 %RH (90–100 %RH) Humidity sensor HUMICAPâ 180R Stability ±2 %RH over 2 years Temperature Measurement range −40 … +60 °C (−40 … +140 °F) Accuracy: at 0 … +40 °C (+32 … +104 °F) ±0.2 °C (±0.36 °F) at −40 … 0 °C (−40 … +32 °F) and +40 … +60 °C (+104 … +140 °F) ±0.4 °C (±0.72 °F) Temperature sensor Pt1000 RTD Class F0.1 IEC 60751 Analog outputs Accuracy at +20 °C (+68 °F) ±0.2 % of FS Temperature dependence ±0.01 % of FS/°C (±0.006 % of FS/°F) Operating environment Operating temperature −40 … +60 °C (−40 … +140 °F) IP rating 1) IP54 1) Not applicable with the plastic grid filter. Compliance EU directives and regulations EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU) amended by 2015/863 Electromagnetic compatibility (EMC) EN 61326‑1, basic electromagnetic environment Compliance marks CE, RCM, UKCA Inputs and outputs Power consumption 1 mA average, max. peak 5 mA Operating voltage 1) With 1 V / 2.5 V output 5–28 V DC With 5 V output 8–28 V DC With loop power converter 8–28 V DC With digital output 5–28 V DC Start-up time Probes with analog output 4 s at operating voltage 13.5– 16.5 V DC 2 s at other valid operating voltages Probes with digital output 1 s Outputs 2 channels 0–1 V DC / 0–2.5 V DC / 0–5 V DC / 1– 5 V DC 1-channel loop-power converter (separate module, compatible with humidity accuracy only) 4–20 mA Digital output (optional) RS-485 2-wire half duplex, supports Modbus RTU External loads 0–1 V RL min 10 kΩ 0–2.5 V /0–5 V RL min 50 kΩ Output parameters Relative humidity, temperature, dew point temperature, wet bulb temperature, absolute humidity, mixing ratio, enthalpy 1) Use lowest available operating voltage to minimize heating. Mechanical specifications Cable connector 4-pin M8 (IEC 60947-5-2) Materials Body PC/ABS blend Grid filter PC (glass reinforced) Cable Polyurethane or FEP Weight Probe 9 g (0.3 oz) Probe with 0.3 m (1 ft) cable 20 (0.7 oz) |
|
|
Link URL |
| Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Liên kết đến bảng dữ liệu | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |